Arming/Disarming the Security Panel

1. Set up a PGM output to Remote Arming in C24 Communications
2. Ensure this PGM output is connected to a relay to their security panel zone
3. Set up the zone on the security panel as momentary or maintained arming
a. If the Security Panel uses Momentary key switching, the configuration on Communicator PGM shall be with a time
field of 05 (in this configuration, both arm and disarm will generate the pulse)
b. If the security Panel uses maintained key arming, the configuration on the communicator PGM shall be filled with a
time field of 00
4. Optionally the panel arm state can be configured for the communicator to detect by setting a panel PGM output to reflect
panel arm state, have that relay connected to a communicator zone configured to follow panel arm state.

Remote Control of PGM

1. Set up a PGM or both PGM output to Remote Control PGM configuration
a. PGM can be latched or timed
i. setting the PGM timer to 00 will configure the PGM to be latched, it will not turn off unless the turn off command is
received
ii. setting the PGM timer with a time value between 1 second to 255 seconds will configure the PGM to be timed,
the PGM will activate
2. Configure in C24 Communications the Phone Number allowed to use SMS command and control and the access code
a. Up to 6 different phone numbers can be programmed to perform SMS command and control
b. The password can be 4 to 8 alphanumeric characters and it will not be case sensitive
The SMS command and control can be sent in the following format:
For arming/disarming the Security Panel
Arm <access code>, example Arm 12345678
For activating/deactivating a specific PGM
Activate <PGM #> <access code>, Activate 1 12345678
The following SMS command and control operations are available.
Arming
l
Disarming
l
Activate PGM
l
Deactivate PGM
l
Language Command Label (shall not be case sensitive)
English
Arm
French
Armement
Spanish Armado
Language Command Label (shall not be case sensitive)
English
Disarm
French
Desarmement
Spanish Desarmado
Language Command Label (shall not be case sensitive)
English
Activate
French
Activation
Spanish Activar
Language Command Label (shall not be case sensitive)
English
Deactivate
French
Desactivation
Spanish Desactivar