Identification Of Parts - DSC 3G4010 Installation Manual

3g hspa cellular alarm communicator
Hide thumbs Also See for 3G4010:
Table of Contents

Advertisement

1
All circuits are classified for UL installations as Power Limited/Class II Power Limited except for the battery leads which are not
power limited. Do not route any wiring over circuit boards. Maintain at least 1" (25.4mm) separation. A minimum 1/4" (6.4mm) of
separation must be maintained at all points between Power Limited wiring and all other non-Power Limited wiring. Route wires
as indicated above.
For ULC Commercial Fire Monitoring Installations, connections between the fire alarm control panel inputs/outputs (telephone
interface Tip/Ring or output relay contacts) and 3G4010 inputs/outputs (T1/R1, Z1-Z4, PGM1-4) shall be run in metallic conduit
within 18m(ULC) and in the same room.
1
2
3
4
5
6
7
8
This equipment 3G4010 is fixed and shall be installed by Service Persons only (Service Person is defined as a person having
the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in

Identification of Parts

Part
Metal Casing
3G Antenna
Antenna Mounting Hardware
Anchor Screw Holes (3mm)
Antenna Connector
SIM Card Holder
Status LEDs (See page 9)
3G (HSPA) Radio Module
Figure 1: Parts
5
4
6
UA673
C ON3
9
11
14
9
10
11
12
13
14
15
6
2
3
4
8
LE D1
LE D2
LE D3
LE D4
+
-
Part
PC-Link Connector
Tamper Switch
Terminal Blocks
Battery Leads
Cable Entry
Earth Ground Wire
12V/1.2Ah Battery
(not included)
10
tie wrap
13
12
15
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents