Chapter 4 Panel Display and Operation

4.3.4 Positive and Negative Sign Setting

Display Symbol

4.3.5 Monitor Display

When the drive is applied to the power, the display will show the monitor displayed symbol
for a second, and then enter into the Monitor Mode. In Monitor Mode, the UP / DOWN Key
can change the desired monitor variable. Or, the user can directly change parameter P0-
02 to set the monitor code. When the power is applied, it will display ASDB2 first. When
the value of P0-02 is 4, it will display the pulse number of pulse command.
P0-02
Monitor Displayed
Setting
0
1
2
3
4
5
6
7
8
9
4-4
When entering into the Editing Setting Mode, pressing UP /
DOWN Key can increase or decrease the displayed content.
The SHIFT Key can change the desired adjusted carry value.
(The carry value is blinking at the moment.)
Pressing the SHIFT Key for two seconds can switch the positive
(+) and negative (-) sign. If the parameter is over the range after
switching the positive or negative sign, then it cannot be
switched.
Symbol
Motor feedback pulse number (after the
scaling of electronic gear ratio) (User unit)
Input pulse number of pulse command
(after the scaling of electronic gear ratio)
(User unit)
The difference of error pulse number
between control command pulse and
feedback pulse number (User unit)
Motor feedback pulse number (encoder
unit, 1600000 pulse/rev)
Input pulse number of pulse command
(before the scaling of electronic gear ratio)
(encoder unit)
Error pulse number (after the scaling of
electronic gear ratio) (encoder unit)
Input frequency of pulse command
Motor speed
Speed input command
Speed input command
Description
Description
ASDA-B2
Unit
[user unit]
[user unit]
[user unit]
[pulse]
[pulse]
[pulse]
[Kpps]
[r/min]
[Volt]
[r/min]
Revision May, 2018