Jog Mode - Delta ASD-B2-1521-F User Manual

Asda-b2 series
Hide thumbs Also See for ASD-B2-1521-F:
Table of Contents

Advertisement

Chapter 4 Panel Display and Operation

4.4.2 JOG Mode

When it is in Parameter Mode, select P4-05 and follow the setting method below for JOG
operation.
(1) Press the SET Key to display the speed value of JOG. The default value is 20 r/min.
(2) Press UP or DOWN Key to adjust the desired speed value of JOG. It is adjusted to
100 r/min in the example.
(3) Press the SET Key to display JOG and enter JOG mode.
(4) When it is in JOG Mode, press UP or DOWN Key to enable the servo motor in forward
or reverse direction. The servo motor stops running as soon as the user stops
pressing the key. JOG operation is working only when it is Servo ON.
4-8
ASDA-B2
Revision May, 2018