Manufacturer's Seal

Wall-mounting f6
Rack-mounting f9
3.2

Verification Seal

Note
Wall-mounting f6
Rack-mounting f9
Note
Landis+Gyr
30/88
Sealing at
manufacturer's site
1 left
manufacturer's seal
1 right
manufacturer's seal
2
none
6
binder
The manufacturer's seal is secured after the meter has been assembled,
tested, and calibrated.
For the f6, the manufacturer's seal secures the meter cover so that the
front window can not be opened without removing the seal. The ZxQ is
delivered with two manufacturer's seal; one at the upper left side of the
front window and one on the upper right side. Once certified, the
manufacturer's seal on the upper right side of the front window is replaced
with the verification seal.
For the f9, the manufacturer's seal secures the meter base so that it can
not be opened without removing the seal. The ZxQ is delivered with two
manufacturer's seals at the back of the base; one at the upper right side
and one at the lower left side. Once certified, one or both of the
manufacturer's seals is replaced with the verification seal.
The verification seal is secured after the meter's measuring capability has
been verified.
Damaging the verification seal
In countries with an obligatory verification, the verification seal is awarded
by the verification body and guarantees the correct measurement
performance of the meter according to the local regulations.
Breaking a verification seal renders the official verification invalid. Breaking
a verification seal also renders the guarantee invalid, as defined in the
general delivery conditions.
Once certified, the manufacturer's seal on the upper right side of the front
window is replaced with the verification seal.
Once certified, one or both of the manufacturer's seal at the back of the
meter case is replaced with the verification seal.
Removal of Communication Unit on rack mounted version f9
For f9, the communication unit can only be removed or exchanged for
another communication unit or dummy by opening the meter case and
breaking the verification seal.
Sealing at utility's site -
no verification necessary
manufacturer's seal
manufacturer's seal
utility's seal
utility's seal
H 71 0200 0215 f en - ZMQ202 / ZFQ202 - User Manual
Sealing at utility's site -
verification necessary
manufacturer's seal
verification seal
verification seal
verification seal
Mechanical Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zfq202

Table of Contents