20
en | Configuration
5.3.5

Advanced Network Settings page

Figure 5.4: Advanced Network Settings page
Legacy Panel Mode
Default: 0 (Disable)
Selections: 0, 1
0: Legacy Panel Mode is disabled.
1: Legacy Panel Mode is enabled.
This option allows the module to support legacy control panels that communicate using
Datagram Mode 0. When Legacy Panel Mode is enabled, the module uses the Local Port
parameter as both the source port and destination port for communication.
The control panels that use Legacy Panel Mode are:
Port 77EE Configuration Enable
Default: No
Selections: Yes, No
Yes: The network configuration port is enabled.
No: The network configuration port is disabled.
The Conettix D6200 Programming/Administration Software uses this port to find devices on
its local network.
2016.08 | 08 | F.01U.266.226
GV2 v7.05 and lower
D9412G/D7412G/D7212G v6.99 and lower
DS7400XiV4
Installation and Operation Guide
Conettix Ethernet Communication Module