Conettix Ethernet Communication Module
TCP/UDP Port Number
Default: 7700
Selection: 0 to 65535
This parameter sets the local port number on which the module listens for in-coming network
traffic. This port is also the source port for outgoing communication.
The TCP/UDP Port is typically configured as 7700 when the control panel is communicating
with a central station receiver, RPS, Automation or Remote Security Control. Port numbers are
assigned in various ways based on three ranges:
Note: In order to limit unwanted traffic, select a number above 1023.
Legacy TCP Automation Enable
Default: No
Selection: Yes, No
When enabled, a single TCP connection with no security is allowed.
TCP Keep Alive Time
Default: 45
Selection: 0 – 65 (0: Disable, 1 - 65: Keepalive Time in sec)
Select how many seconds the unit waits during a silent connection before attempting to see if
the currently connected network device is still on the network. If there is no response, it
drops the connection.
Bosch Security Systems, Inc.
System Ports: 0 to 1023
User Ports: 1024 to 49151
Dynamic or Private Ports: 49152 to 65535
Installation and Operation Guide
Configuration | en
19
2016.08 | 08 | F.01U.266.226