en | Configuration
Default: Blank
Selections: Twenty alphanumeric characters
Use this parameter to create a simple description for the unit, shown in the web configuration
pages.
Notice!
Do not use the double quote character (") as it causes unexpected results.
5.3.9

Factory Default page

Figure 5.8: Factory Default page
You can return the module to the factory default settings by clicking on the Factory Default
menu.
Click Cancel to cancel the factory default reset. If you select OK, all configuration options are
returned to the factory default settings.
Notice!
Returning the module to its factory default settings might cause the module to terminate the
current web browsing session. If connected to a compatible SDI2 control panel, the control
panel overwrites the factory default settings with the control panel's settings. To avoid the
control panel settings overwriting Configuration Page settings, set Panel Programming
Enable to No after restoring the module to factory default, but before pressing Save and
Execute.
2016.08 | 08 | F.01U.266.226
Installation and Operation Guide
Conettix Ethernet Communication Module