Show The Firmware Version - Bosch B426 Installation And Operation Manual

Conettix ethernet communication module
Table of Contents

Advertisement

Conettix Ethernet Communication Module
LINK (yellow) LED pattern
Flashing
Tab. 6.4: Ethernet Link LEDs descriptions
Trouble conditions indicated through LEDs
Condition
Network cable
disconnected
Obtaining an IP address
Low bus voltage
Internal failure
Tab. 6.5: Trouble conditions
Notice!
When the tamper switch is closed, all module LEDs are Off.
6.1

Show the firmware version

To show the firmware version using an LED flash pattern:
When the tamper switch is activated (open to closed), the heartbeat LED stays Off for 3 sec
before indicating the firmware version. The LED pulses the major, minor, and micro digits of
the firmware version, with a 1 sec pause after each digit.
The following is an example: The version 1.4.3 would show as LED flashes:
[3 second pause] *__****__*** [3 second pause, then normal operation].
Bosch Security Systems, Inc.
On Steady
Heartbeat
If the optional tamper switch is installed:
With the enclosure door open, activate the tamper switch.
If the optional tamper switch is NOT installed:
Momentarily short the tamper pins.
Installation and Operation Guide
Maintenance and troubleshooting LEDs | en
100Mb (green) LED pattern
On Steady
On Steady
Transmit (TX)
On Steady
On Steady
On Steady
On Steady
Function
100Base-TX link
100Base-TX activity
Receive (RX)
Off
Flashes once every
1 sec
2 quick flashes
Off
every 1 sec
3 quick flashes
Off
every 1 sec
Off
2016.08 | 08 | F.01U.266.226