en | Appendix
2.
3.
4.
5.
8.2.3

Use Auto IP with a directly connected module

If the module is connected directly to a computer (laptop or PC) and is not connected to a
network (no network hub, router, or switch is connected), you can use the module's AutoIP. to
connect and program the module without knowing the IP.
Notice!
If you cannot connect with the AutoIP option, you might need to change the web browser
configuration so that it does not use a proxy server. Also ensure the computer has AutoIP
enabled. Refer to the browser's online help for instructions on disabling proxy service.
If the module's IP address is not recorded in the host computer's ARP table and you do not
know the address, follow the steps below.
Using the AutoIP:
1.
2.
3.
4.
5.
If AutoIP does not work on the host computer, a new registry key might be required to enable
AutoIP. Be sure to obtain permission from your company IT department before changing the
registry.
Enabling AutoIP on the host computer with a new registry key:
1.
2.
3.
4.
5.
2016.08 | 08 | F.01U.266.226
At the Tools menu, press [ENTER]. The keypad prompts you to enter the installer
passcode.
Enter the installer passcode and press [ENTER].
Go to the IP Diagnostics > B420 Module (1-2) > Settings menu option, and then press
[NEXT] twice to access the IPaddress.
When the you finish viewing the information, press [ESC] to exit the menu.
Remove power from the module.
Disconnect the module from the network.
Connect the B426 directly to the Ethernet port on a computer, power up, and wait 60
sec. If AutoIP service is enabled on your computer, a 169.254.XXX.XXX address should
now be assigned to your computer.
Open an internet browser (Microsoft Internet Explorer 6 or higher, or Mozilla Firefox 3 or
higher) and type in the default AutoIP address for the B426: 169.254.1.1, and press
[Enter].
Enter the password (default is B42V2) and click Login. The Device Information page
opens.
Open Notepad and create a new file called AutoIP.reg.
In Notepad, include the following text:
Windows Registry Editor Version 5.00
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters]
"IPAutoconfigurationEnabled"=dword:00000001
Save the file to a location on the host computer that you can easily find.
Navigate to the saved file and double-click on it to add it to the host computer's registry.
Restart the host computer.