148
2.
Connect the valve (4) to the hose (5) for the suction container.
3.
Connect the connection hose (6) for the compressed air to
the valve (4).

7.13.2 Setting the operating pressure

Information
The operating pressure is 6.5 bar.
The operating pressure is preset and cannot be adjusted.

7.14 Checking the lubrication

The wicks, felt, looper and needle bar must all be lubricated with
a little oil when setting up the machine, or after longer standstill
periods.
All moving parts in the machine are lubricated via an oil-wick
system from 2 oil reservoirs.
CAUTION
Risk of environmental damage from oil!
Oil is a pollutant and must not enter the sewage
system or the soil.
Carefully collect up used oil.
Dispose of used oil and oily machine parts in
accordance with the legal regulations.
Use only DA 10 lubricant or an equivalent oil conforming to the
following specifications for lubrication:
• Viscosity at 40° C: 10 mm²/s
• Flash point: 150° C
Operating Instructions 581 - 01.0 - 05/2016