13.4 Change Codes (Adding codes, tags and keyfobs)

The 'Change Codes' function allows adding, editing and deleting of user codes and the edit of
the master manager code.
Tags can also be programmed here for any user code, as well as wireless keyfobs (which are
each assigned to a user)
The control panel can have up to 80 user codes/tags (up to 32 users can be assigned to wireless
keyfobs)
Button Actions: Each wireless keyfob has 4 buttons that can be programmed for any of the
functions below:
No Action = Disables the button
Show Status = If the keyfob is learnt the LED will flicker when asked for the status.
Set Area = Sets the chosen area
Unset Any Area = Unsets any area on the system
Latch Output = Enables an output that your engineer may have programmed
Timed Output = Enables an output for a period of time that your engineer may have
programmed
Flexi-Set: Flexi-set allows you to choose which level/area to set if a user code is assigned to one
or more levels/areas. If this function is disabled, when a user code is entered, the system will
automatically set the levels/areas that the code is assigned to.
 Use the b and A keys to scroll to
'Change Codes'. Press the I key.
 To edit user codes, press the I key.
 Enter the user number to be edited
 Press the I key
 Enter the new code / present a tag /
press a keyfob button (this display
won't be displayed if a keyfob is
assigned)
 Once 'asterisks' appear, the tag or
keyfob will be assigned to this user.
 Press the I key
Programming Wireless Keyfobs
If a keyfob is programmed, user name will be
displayed first.
 Enter the user name (for help on
predictive text please see page 8)
I
Press the
key.