Change Codes (Adding Codes, Tags And Keyfobs); Button Actions; Flexi Set - Pyronix Enforcer 32-W User Manual

Wireless alarm system
Table of Contents

Advertisement

13.5 Change Codes (Adding codes, tags and keyfobs)

The 'CHANGE CODES' function allows adding, editing and deleting of user codes, tags and
keyfobs. The master manager code can also be changed.
The control panel can have up to 80 user codes or tags. Up to 32 keyfobs can be learnt.

13.5.1 Button Actions:

Each wireless keyfob has 4 buttons that can be programmed for any of the functions below:
No Action = Disables the button
Show Status = If the keyfob is learnt the LED will flicker when asked for the status.
Set Area = Sets the chosen area
Unset Any Area = Unsets any area on the system
Latch Output = Enables an output that your engineer may have programmed
Timed Output = Enables an output for a period of time that your engineer may have
programmed

13.5.2 Flexi Set

Flexi-set allows you to choose which level/area to set if a user code is assigned to one or
more levels/areas. If this function is disabled, when a user code is entered, the system will
automatically set the levels/areas that the code is assigned to.
Press b or A to scroll to 'CHANGE
CODES'. Press I.
To add a new code, tag, or keyfob press
I. Press A to delete or change a user
code (see further down for details).
Press [ or ] to choose a user
number. Press I.
Enter the new code, present a tag or
press and hold a keyfob button until the
display changes. Once 'asterisks' appear,
the tag or user code will be now
assigned to this user. Press I.
Programming Wireless Keyfobs
If a keyfob is programmed, the 'User
Name' will be displayed on the keypad.
Enter the user name. Press I.
Press [ or ] to choose the button to
program. Press I.
Press [ or ] to choose the action
assigned to the button. Press I.
User Manual
Page: 18

Hide quick links:

Advertisement

Table of Contents