The setting of the switches on the AJ65BT-RPI-10A/10B module is
described below.
(1) Transmission speed setting switch
This switch is used to set the transmission speed of the AJ65BT-
RPI-10A/10B module.
For detail of the setting, refer to Section 4.3.
POINT
• Set to the same state of setting as set in the master station.
• The states of setting of the transmission speed setting switch obtained when
the module power supply is set from OFF to ON or the reset switch is set to
OFF become effective. When the states of setting are changed with the
module power supply turned ON, perform the above operations again.
(2) Station number setting switches
The station number setting switches are used to set the station
number of the AJ65BT-RPI-10A/10B. It is also used to set whether
the monitor function is used or not. For full information on the
setting, refer to Section 4.3. For full information on the monitor
function, refer to Chapter 5.
POINT
The setting of the station number setting switches is made valid when the
module power is switched from OFF to ON. If the setting has been changed with
the module power ON, perform the above operation again.