Technical Data; Angle Measurement - Leica TS12P User Manual

Robotic total station
Table of Contents

Advertisement

7
7.1
Accuracy
Characteristics
TS12P, Technical Data

Technical Data

Angle Measurement

Available angular
accuracies
["]
2
3
5
7
Absolute, continuous, diametric.
Standard deviation Hz, V,
ISO 17123-3
[mgon]
0.6
1.0
1.5
2.0
Display resolution
["]
[mgon]
0.1
0.1
0.1
0.5
0.1
0.5
0.1
0.5
57