Distance Measurement With Reflectors - Leica TS12P User Manual

Robotic total station
Table of Contents

Advertisement

7.2
Range
Atmospheric
conditions
Accuracy
Characteristics
TS12P, Technical Data

Distance Measurement with Reflectors

Reflector
Standard prism (GPR1)
Three standard prisms (GPR1) 2300
360° prism (GRZ4, GRZ122)
360° Mini prism (GRZ101)
Mini prism (GMP101)
Reflector tape (GZM31)
60 mm x 60 mm
Machine Automation power
prism (MPR122)
For Machine Control
purposes only!
Shortest measuring distance: 1.5 m
Range A:
Strong haze, visibility 5 km; or strong sunlight, severe heat shimmer
Range B:
Light haze, visibility about 20 km; or moderate sunlight, slight heat
shimmer
Range C:
Overcast, no haze, visibility about 40 km; no heat shimmer
Measurements can be made to reflector tapes over the entire range without external
ancillary optics.
Accuracy refers to measurements to standard prisms.
EDM
std. dev.
measuring mode
ISO 17123-4,
standard prism
Standard
1 mm + 1.5 ppm
Fast
3 mm + 1.5 ppm
Tracking
3 mm + 1.5 ppm
*1 does not include radio transfer time to the CS.
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
The display resolution is 0.1 mm.
Principle:
Type:
Carrier wave:
Measuring system:
Range A
[m]
[ft]
1800
6000
7500
800
2600
450
1500
800
2600
150
500
800
2600
std. dev.
ISO 17123-4,
tape
5 mm + 2 ppm
5 mm + 2 ppm
5 mm + 2 ppm
Phase measurement
Coaxial, visible red laser
658 nm
System analyser basis 100 MHz - 150 MHz
Range B
Range C
[m]
[ft]
[m]
3000
10000
3500
4500
14700
5400
1500
5000
2000
800
2600
1000
1200
4000
2000
250
800
250
1500
5000
2000
Measurement
time, typical [s]*
2.4
0.8
< 0.15
[ft]
12000
17700
7000
3300
7000
800
7000
1
58

Hide quick links: