7.8
Telescope
Compensator
Level
Control unit
Instrument Ports
TS12P, Technical Data

General Technical Data of the Instrument

Magnification:
Clear objective diameter:
Focusing:
Field of view:
Angular accuracy
Setting accuracy
TS12P ["]
["]
2
0.5
3
1.0
5
1.5
7
1.5
Circular level sensitivity:
Electronic level resolution:
Display:
Keyboard:
Angle Display:
Distance Display:
Touch screen if fitted:
Port
Name
Port 1
Port 1
Port 2
Handle
Port 3
BT
30 x
40 mm
1.7 m/5.6 ft to infinity
1°30'/1.66 gon.
2.7 m at 100 m
[mgon]
0.2
0.3
0.5
0.5
6'/2 mm
2"
1/4 VGA (320 x 240 pixels), colour, graphics
capable LCD, illumination, touch screen
28 keys
including 6 function keys and 12 alphanumeric
keys, illumination
360°'", 360° decimal, 400 gon, 6400 mil, V %
m, ft int, ft us, ft int inch, ft us inch
Toughened film on glass
Description
• 5 pin LEMO-0 for power, communication, data transfer.
• This port is located at the base of the instrument.
• Hotshoe connection for RadioHandle with RCS.
• This port is located on top of Communication side cover.
• Bluetooth module for communication.
• This port is housed within Communication side cover.
Setting range
[']
[gon]
4
0.07
4
0.07
4
0.07
4
0.07
65