Operation; Instrument Setup - Leica TS12P User Manual

Robotic total station
Table of Contents

Advertisement

4
4.1
Description
Setup
step-by-step
TS12P, Operation

Operation

Instrument Setup

This topic describes an instrument setup over a marked ground point using the laser
plummet. It is always possible to set up the instrument without the need for a marked
ground point.
Important features
• It is always recommended to shield the instrument from direct sunlight and avoid
uneven temperatures around the instrument.
• The laser plummet described in this topic is built into the vertical axis of the instru-
ment. It projects a red spot onto the ground, making it appreciably easier to centre
the instrument.
• The laser plummet cannot be used with a tribrach equipped with an optical
plummet.
3
1
TS12_019
Step
Description
Shield the instrument from direct sunlight and avoid uneven temperatures
around the instrument.
1.
Extend the tripod legs to allow for a comfortable working posture. Position
the tripod over the marked ground point, centring it as well as possible.
2.
Fasten the tribrach and instrument onto the tripod.
3.
Turn on the instrument by pressing ON for 2 s. Press USER, STAT (F3) to
access the Status Menu. Select Level & Laser Plummet to access STATUS
Level & Laser Plummet, activating the laser plummet.
4.
Move the tripod legs (1) and use the tribrach footscrews (6) to centre the
plummet (4) over the ground point.
5.
Adjust the tripod legs to level the circular level (7).
6.
By using the electronic level turn the tribrach footscrews (6) to precisely
level the instrument.
7.
Centre the instrument precisely over the ground point (4) by shifting the
tribrach on the tripod plate (2).
8.
Repeat steps 6. and 7. until the required accuracy is achieved.
2
6
1
1
7
5
5
4
5
36

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents