● Switch on the monitor with function 1.
● Carry out a test seam.
● Check, whether the trigger signals with the largest hook loop and in t.d.c. take-up lever
are both in the maximum range of the thread strength signal.
● If necessary alter the value for parameter 2011 (largest hook loop, standard value: "344")
accordingly.
● If necessary alter the value for parameter 2013 (t.d.c. take-up lever, standard value: "74")
accordingly.
● Carry out another test seam and check the altered value.
● If necessary repeat the procedure until the setting for the trigger signals is correct.
● Enter the values for the speed (500 min-1) and for the parameters 2011 and 2013 in the
calibration certifi cate.
● Call up the mode selection function.
5
Check the zero position of the monitor power signal
.02.03
(Item 3 of the calibration certifi cate)
● Call up the "tools" function.
● Call up the menu for adjusting the parameter values.
● Call up parameter 2010.
● Check whether the value "244" is set. If necessary enter this value.
● Call up the mode selection function.