Calibration
● Call up function 1.
● Do not attach a weight, or remove the weight.
● Acknowledge the measurement.
● Record the value from box 2 in the calibration certifi cate.
● Call up function 3.
● Attach appropriate weight (500 cN)
● Acknowledge the measurement.
● Record the value from box 4 in the calibration certifi cate.
● Carry out all measurements from 100 cN to 1000 cN in succession and record the corre-
● After completing all measurements, quit the calibration menu.
126
The measured value appears in box 2.
The measured value appears in box 4.
sponding values in the calibration certifi cate.