WIRING
TERMINAL CONFIGULATION
①   ②   ③   ④   ⑤   ⑥   ⑦
Power
COM
10.5V to 30VDC
Alarm output
(non-polarity)
Dry contact relay
output 1c N/O-N/C
Wiring distance
Voltage
Wire size
AWG 22 (Dia 0.65mm)
AWG 20 (Dia 0.8mm)
AWG 18 (Dia 1.0mm)
AWG 17 (Dia 1.1mm)
Note)
Maximum wiring distance when two or more sets are
connected is the value above divided by the number of
sets.
4

INSTALLATION

WALL MOUNT

Sensor
①Remove cover from
unit and slide the
mounting plate
upwards to detach
it.
②Pull the wire through on the installation site.
③Make one hole in the grommet on the mounting plate and
pull the wire through it.
 Secure the plate with 4mm self tapping screws
Self tapping screw
holes
Pull the wire through the sensor body (back to front)
and attach it to the terminals on the sensor.
Alarm
NC
NO
Tamper output
Dry contact relay
output 1b N/O
DC12V
DC24V
500' (150m)
5,610' (1700m)
990' (300m)
9,240' (2800m)
1,490' (450m)
13,860' (4200m)
1,815' (550m)
16,830' (5100m)
3.29" (82.5mm)
middle point of the
sensor lenses
CONNECTION
Example connection 1
NC
When cover is
detached
Example connection 2
Example connection 3
④When the wiring is exposed , break knockouts (2 positions)
on the rear of the unit, pull the wire through as in the gure
and attach it to the terminals on the sensor.
⑤After wiring is completed, adjust alignment, attach cover
and check operation.
 (Note : Sealing is not required for unit surround due to
rain-proof construction.)
※The grommet is compatible with a wire of φ0.12" (φ3mm)
to φ0.24" (φ6mm) outer dia.
 When a wire of more than φ0.24 (φ6mm) outer dia. is used,
cut off the dotted line portion on the below
pliers or the like.
 Then use caulking to prevent insects from entering into the
unit.
①②③④
. .
①②③④
①②③④
. .
①②③④
①②③④
Wiring from
the top
Knockout
Grommet
Control panel
(12VDC)
Power
Alarm
signal
Control panel
(12VDC)
Power
Alarm
signal
Control panel
(12VDC)
Power
Alarm(1ch.)
Alarm(2ch.)
Wiring from
the bottom
Knockout
gure using

Advertisement

loading