Download Print this page

Beam Alignment; Operation Check; Response Time - Takex PR-11BE Instruction Manual

Photoelectric beam sensor, outdoor 3.3 to 36ft. (1 to 11m); indoor 3.3 to 49ft. (1 to 15m)

Advertisement

5
ALIGNMENT AND OPERATION

BEAM ALIGNMENT

①Face the sensor lenses to the re ector with its cover
detached.
 Adjust the angle of the sensor unit vertically and
horizontally by looking through the view
between the sensor lenses.
 Adjust it until the center of the re ector can be seen in the
middle of the view nder.
②Supply power to the sensor.
 When the sensor and re ector are properly installed at the
same height, alarm LED will remain OFF.
③After con rming that the alarm LED is OFF, place the
attenuation sheet on the optics of the sensor and check if
the attenuation LED is OFF.
 Please note that there are two types of attenuation sheets.
 (indoor use and outdoor use)
4)If the attenuation LED lights, make adjustment again
until it turns OFF.
5)Fine tuning should be done by monitoring the output
voltage using a volt meter.
(See the table below.) until obtaining the peak voltage.
Monitor output voltage
2.6V or more
1.4 to 2.6V
less than 1.4V
・The above voltage shows the monitor output when
Note :
the lenses are covered by the attenuation sheet.
・Using the attenuation sheet and a voltmeter ensures
optimum performance of the sensor.
・After adjustment, take out attenuation sheet.

OPERATION CHECK

・After installing the sensor and making the alignment
adjustment, check the operation of the sensor with its
cover attached by looking at the alarm LED on the sensor.
①Make sure that the alarm LED is OFF.
②When the infrared beam is interrupted, the alarm LED
lights.
 It indicates that the operation is normal.
 The relay operates during the interruption time for a
minimum of 2 seconds.
③Walk through the infrared beam between the sensor and
the re ector and make sure that the alarm LED lights up
and then goes off.
6

RESPONSE TIME

Adjust response time as follows. The unit does not detect a passing object faster than the response time setting. If the
response time is set longer, the unit does not detect human beings. Adjust to a little longer response time in a site where large
passing objects, such as birds, newspaper or falling leaves may pass through the beam path.
Response time adjustment
(0.3)
0.7
Response time
(sec.)
0.05 (standard)
nder placed
Beam level (outdoor, indoor)
Best
Good
Re-adjustment
Response 0.05 sec.
Run at full speed
Note :
Unreasonably longer response time may cause undetection of a human being.
View finder
Vertical adjustment screw
Clockwise : Upward
Counterclockwise : Downward
減衰シート
Alarm LED
Make sure the light turns off(②)
Attenuation LED
Make sure the light turns off(③,④)
volt meter
Alarm LED
Sensor
Response 0.3 sec.
Response 0.7 sec.
Walk with quick steps
View finder
Horizontal
adjustment
Attenuation sheet
Reflector
Walking

Advertisement

loading