Chapter 1: Overview

Enabling SML

To enable SML on the unit, set the SML ON/OFF DIP switch on the bottom
of the unit to the ON position. See Figure 9.
Note
The unit is shipped with SML in the ON position.
SML ON/OFF
Figure 9. SML ON/OFF DIP Switch

Power Source

The media converter is powered via a Micro-B USB connector and
provided Micro-USB to Type-A USB cable. The power source can be a PC
USB port or the optional external AC/DC power adapter.
Depending on the customer order, the AC/DC power adapter is included
with the media converter for standalone operation. The power adapter
supplies 5 VDC to the media converter. Allied Telesis supplies a UL
approved safety-compliant AC power adapter for the 120 and 240 VAC
versions with a regulated output of 5 VDC. The power required for the
media converter is 5 VDC, 0.5 A.