  • Page 1: Installation Guide

    AT-FS232 AT-FS232/1 AT-FS232/2 AT-FS232/3 AT-FS232/4 Bridging Converters Installation Guide PN 613-50358-00 Rev B...
  • Page 2 Copyright  2003 Allied Telesyn, Inc. 960 Stewart Drive, Suite B, Sunnyvale, CA 94085, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
  • Page 3: Electrical Safety And Emission Compliance Statement

    Manufacturer Telephone: 408-730-0950 Declares that the product: Bridging Converter Model Numbers: AT-FS232, AT-FS232/1, AT-FS232/2, AT-FS232/3, AT-FS232/4 This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 4 Electrical Safety and Emission Compliance Statement RFI Emission FCC Class B, EN55022 Class B, VCCI Class B, C-TICK Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
  • Page 5 AT-FS232 and AT-FS232/x Series Installation Guide Importante: El Apéndice B contiene mensajes de seguridad traducidos para la instalación de este equipo. Cuando vea el símbolo , vaya al Apéndice B para ver el mensaje de seguridad traducido a su idioma.
  • Page 7: Table Of Contents

    Table of Contents Electrical Safety and Emission Compliance Statement ...... iii Table of Contents ..................vii Welcome to Allied Telesyn ................ix Where to Find Web-based Guides ..............ix Document Conventions ..................ix Contacting Allied Telesyn ................. x Online Support ................... x Email and Telephone Support ..............
  • Page 8: Table Of Contents

    Table of Contents Chapter 2 Installing the Bridging Converter ............15 Verifying Package Contents ................15 Planning the Installation ................16 Selecting a Site ..................18 Reviewing Safety Guidelines ..............19 Installing the Bridging Converter ..............20 Connecting a 12VDC Powered Unit ............24 Wiring and Connecting a 12-50VDC Powered Unit .......
  • Page 9: Welcome To Allied Telesyn

    Welcome to Allied Telesyn This guide contains instructions on how to install the AT-FS232 and AT-FS232/x Series Bridging Converters. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com offers you an easy way to access the most recent documentation, software, and technical information for all of our products.
  • Page 10: Contacting Allied Telesyn

    Welcome to Allied Telesyn Contacting Allied Telesyn This section provides Allied Telesyn contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesyn Knowledge Base from the following web site: http://kb.alliedtelesyn.com. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
  • Page 11: Overview

    The fiber optic port operates at 100 Mbps, while the twisted pair port operates at 10 Mbps or 100 Mbps. Both ports feature half- and full-duplex operation. AT-FS232 and AT-FS232/x Series Bridging Converters can be installed on a desktop or in an AT-MCR12 chassis. These bridging converters are easy to...
  • Page 12 Overview Figure 1 illustrates the front panel of the AT-FS232 Bridging Converter. Figure 1 AT-FS232 Front Panel Figure 2 illustrates a front panel of an AT-FS232/x Series Bridging Converter. SINGLE MODE Figure 2 AT-FS232/x Series Front Panel (AT-FS232/1 Model) The back panel of the AT-FS232 and AT-FS232/x Series Bridging Converters features a DC power connector and DIP switches for manually configuring the ports.
  • Page 13 AT-FS232 and AT-FS232/x Series Installation Guide Figure 3 illustrates the back panel of the AT-FS232 and AT-FS232/x Series Bridging Converters with a 12VDC power connector. PORT SPEED DUPLEX AUTO (Mbps) MODE 12 V D C HALF FULL Figure 3 Back Panel of the AT-FS232 and AT-FS232/x Series Bridging Converters...
  • Page 14 100Base-FX 10Base-T/100Base-TX Model Maximum Maximum Connector Operating Connector Operating Distance Distance AT-FS232 2 km (1.24 mi) RJ-45 100 m (328 ft) AT-FS232/1 15 km (9.3 mi) RJ-45 100 m (328 ft) AT-FS232/2 40 km (24.8 mi) RJ-45 100 m (328 ft) AT-FS232/3 70 km (43.4 mi)
  • Page 15: External Power Supply

    AT-FS232 and AT-FS232/x Series Installation Guide External Power Supply 12VDC Power Supply The 12VDC-version bridging converters come with the AC/DC power adapter illustrated in Figure 5. This is an approved safety compliant AC power adapter for the 100 and 240V AC versions with an unregulated output of 12VDC.
  • Page 16: Key Features

    Overview Key Features The AT-FS232 and AT-FS232/x Series Bridging Converters have the following features: ❑ LEDs for unit and port status ❑ Auto MDI/MDI-X ❑ Mode selection button that toggles between Link Test, MissingLink , and Smart MissingLink ❑ DIP switches for configuring the ports ❑...
  • Page 17: Status Leds

    AT-FS232 and AT-FS232/x Series Installation Guide Status LEDs Table 2 defines the LEDs for the AT-FS232 and AT-FS232/x Series Bridging Converters. Table 2 Status LEDs Color Description Green Power is applied to the unit. AUTO NEG Green Auto-negotiation on the twisted pair port is enabled.
  • Page 18: Twisted Pair Port

    If desired, Auto-Negotiation can be disabled and you can set the duplex mode manually. Note In order for the twisted pair port on the AT-FS232 and AT-FS232/x Series Bridging Converters to successfully Auto-Negotiate its duplex mode with an end-node, the end-node should also be using Auto- Negotiation.
  • Page 19: Auto Mdi/Mdi-X

    When the port on the AT-FS232 or AT-FS232/x Series converter is not set to Auto-Negotiation, the port defaults to MDI-X. To connect to an end-node that has the same wiring configuration, such as MDI-X to MDI-X, you would use a crossover twisted pair cable.
  • Page 20: Mode Selection Button

    Overview Mode Selection Button Link Test The link test is a fast and easy way for you to test the connections between the bridging converter ports and the end-nodes that are connected to the ports. If a network problem occurs, you can perform a link test to determine which port is experiencing a problem, and so be able to focus your troubleshooting efforts on the cable and end-node where the problem resides.
  • Page 21: Smart Missinglink

    AT-FS232 and AT-FS232/x Series Installation Guide Note MissingLink and Smart MissingLink are disabled when you perform a link test. Consequently, to ensure that MissingLink or Smart MissingLink is enabled on the bridging converter, always set the Mode Selection button so that the ML or SML LED is green during normal network operations.
  • Page 22: Dip Switches

    MAC address table has exceeded its storage limit. Store and Forward The AT-FS232 and AT-FS232/x Series Bridging Converters support store and forward switching at Fast Ethernet full-wire speed in 100 Mbps, half- or full- duplex mode. Packets entering each port are stored in buffers. Once the full packet is received, the bridging converter will forward or discard the packet, depending on its destination address and error status.
  • Page 23: Network Topologies

    FCS before forwarding. Network Topologies Figure 7 illustrates a standalone topology using one AT-FS232 Bridging Converter to interconnect two small networks. ❑ Network 1 has an AT-8024GB switch connected to the 100Base-FX port on the AT-FS232 Converter.
  • Page 24 Overview Figure 7 illustrates a back-to-back topology using two AT-FS232 Bridging Converters to interconnect two small networks. ❑ Network 1 has an AT-8024GB switch connected to the 10Base-T/ 100Base-TX port on the first AT-FS232 Converter. ❑ Network 2 has an AT-8024 switch connected to the 10Base-T/100Base- TX port on the second AT-FS232 Converter.
  • Page 25: Installing The Bridging Converter

    Chapter 2 Installing the Bridging Converter This chapter explains how to install the AT-FS232 and AT-FS232/x Series Bridging Converters. These bridging converters can be installed on a desktop or in an AT-MCR12 chassis. Verifying Package Contents Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance.
  • Page 26: Planning The Installation

    Installing the Bridging Converter Planning the Installation Be sure to observe the following guidelines when planning the installation of your bridging converter. ❑ The end-node connected to the 100Base-FX fiber optic port must be able to operate at 100 Mbps. ❑...
  • Page 27 AT-FS232 and AT-FS232/x Series Installation Guide Refer to Table 4 for the cabling specifications for the fiber optic port when operating in full-duplex mode. Table 4 100Base-FX Fiber Optic Cabling Specifications (Full-duplex) Maximum Operating Maximum Allowable Model Cable Type Distance...
  • Page 28: Selecting A Site

    Installing the Bridging Converter Refer to Table 5 for the cabling specifications for the fiber optic port when operating in half-duplex mode. Table 5 100Base-FX Fiber Optic Ports (Half-duplex) Number of Media Maximum Operating Connected Devices Converters Distance One Media Converter Inline Switch to switch 372 m (1,221 ft) Workstation to switch...
  • Page 29: Reviewing Safety Guidelines

    AT-FS232 and AT-FS232/x Series Installation Guide Reviewing Safety Guidelines Please review the following safety guidelines before you begin to install the bridging converter. Laser Class 1 laser device. Laser Do not stare into the laser beam. Warning Electric Shock Hazard: To prevent electric shock, do not remove the cover.
  • Page 30: Installing The Bridging Converter

    Installing the Bridging Converter Installing the Bridging Converter To install an AT-FS232 or AT-FS232/x Series Bridging Converter, perform the following procedures: Remove all equipment from the package and store the packaging material in a safe place. Note Do not remove the dust cover from the fiber optic port until you are ready to connect the fiber optic cable.
  • Page 31 AT-FS232 and AT-FS232/x Series Installation Guide Table 6 DIP Switch Settings Switch Port Setting Position Description Number Speed (Mbps) Up The twisted pair port operates at 10 Mbps. Down The twisted pair port operates at 100 Mbps. Duplex Mode The fiber optic port operates in half-duplex mode.
  • Page 32 This step does not apply if you are mounting a 12VDC-version bridging converter in an AT-MCR12 chassis. For instructions on how to apply power to a 12VDC version AT-FS232 or AT-FS232/x Series Bridging Converter, refer to “Connecting a 12VDC Powered Unit” on page 24.
  • Page 33 AT-FS232 and AT-FS232/x Series Installation Guide ❑ SC ports consist of two separate connectors, as shown in Figure 10. Each connects to a separate fiber strand. One is for receiving data and the other is for transmitting data. When connecting a fiber optic cable...
  • Page 34: Connecting A 12Vdc Powered Unit

    Installing the Bridging Converter Connecting a 12VDC Powered Unit To apply power to a 12VDC version bridging converter, perform the following steps: Note The power adapter is not used if you install the bridging converter in an AT-MCR12 chassis. Plug one end of the DC power cord to the power receptacle connector labelled 12VDC on the back panel of the bridging converter, as shown in Figure 11.
  • Page 35: Wiring And Connecting A 12-50Vdc Powered Unit

    AT-FS232 and AT-FS232/x Series Installation Guide Wiring and Connecting a 12-50VDC Powered Unit To wire a 12-50VDC powered unit, perform the following step: Before wiring the bridging converter, review the following Warning statements: Warning Only trained and qualified personnel are allowed to install or to replace this equipment.
  • Page 36 Installing the Bridging Converter Plug the power connector to the 12-50VDC receptacle connector in the rear of the converter, as shown in Figure 13. PORT SPEED DUPLEX AUTO (Mbps) MODE 12-50VDC HALF FULL Figure 13 Connecting the Power Connector to the 12-50VDC Version Model Note UL recognized wires of 22-gauge minimum should be provided by the installer.
  • Page 37 AT-FS232 and AT-FS232/x Series Installation Guide Warning When installing this equipment, always ensure that the frame ground connection is installed first and disconnected last. PORT SPEED DUPLEX AUTO (Mbps) MODE 12-50VDC HALF FULL Figure 15 Connecting the Stripped Wire Connect the negative feed wire to the terminal block marked (-).
  • Page 38 Installing the Bridging Converter Secure the power supply cable in the Restricted Access Area using multiple cable ties to minimize the chance of the connections being disturbed by casual contact with the wiring. Warning "Safety Hazard"- Check to see if there are any exposed copper strands coming from the installed wires.
  • Page 39: Warranty Registration

    AT-FS232 and AT-FS232/x Series Installation Guide Warranty Registration When you finish installing the product, you should register your product by completing the enclosed warranty card and sending it in.
  • Page 41: Chapter 3 Troubleshooting

    Chapter 3 Troubleshooting Follow the guidelines below to test and troubleshoot the installation in the event a problem occurs. Note If you change the speed or duplex mode of a port on the bridging converter using the DIP switches, you must power OFF and then power ON the unit to activate the change.
  • Page 42 Troubleshooting ❑ If the twisted pair port is set to Auto-Negotiation, the end node connected to the port should also be using Auto-Negotiation. If the end node is not using Auto-Negotiation and has a fixed duplex mode of full- duplex, a duplex mode mismatch will result. To resolve this, you must disable Auto-Negotiation on the port and adjust the speed and duplex setting manually using the DIP switches.
  • Page 43 AT-FS232 and AT-FS232/x Series Installation Guide If you are still experiencing problems after testing and troubleshooting the installation, contact Allied Telesyn Technical Support for assistance. Refer to “Contacting Allied Telesyn” on page x or visit our web site at www.alliedtelesyn.com for support information.
  • Page 45: Technical Specifications

    Appendix A Technical Specifications Physical Dimensions: W x D x H 10.5 cm x 9.5 cm x 2.5 cm (4.12 in x 3.75 in x 1.0 in) Weight: 294 g (10.4 oz) Environmental Maximum Operating Temperature: 0° C to 40° C (32° F to 104° F) Maximum Storage Temperature: -25°...
  • Page 46: Agency Certifications

    Technical Specifications Agency Certifications Safety Conforms to all standards normally supported by Allied Telesyn products including safety standards UL60950 ( ), EN60950, EN60825 (TUV) CE Compliant Standard IEEE 802.3, IEEE 802.3u Immunity Conforms to EN55024 immunity standard EMI/RFI FCC Class B, EN55022 Class B, VCCI Class B, C-TICK...
  • Page 47: Fiber Optic Port Specifications

    AT-FS232 and AT-FS232/x Series Installation Guide Fiber Optic Port Specifications Table 7 through Table 10 list the specifications for the fiber optic port. Table 7 Fiber Optic Transmitter Fiber Launch Power (dBm) Fiber Optic Optical Model Type Diameter Wavelength Max.
  • Page 48 Minimum Maximum Fiber Model Power/Link Operating Operating Type Budget Distance Distance AT-FS232 50/125 MMF 13.0 dB 2 km (1.25 mi) 62.5/125 MMF 16.8 dB 2 km (1.25 mi) AT-FS232/1 9/125 SMF 16.0 dB 15 km (9.4 mi) AT-FS232/2 9/125 SMF 30.0 dB...
  • Page 49: Pinout Assignments

    AT-FS232 and AT-FS232/x Series Installation Guide Pinout Assignments Figure 17 shows the pin assignments of the RJ-45 connector. Figure 17 RJ-45 Pin Assignments Table 11 lists the 10Base-T/100Base-TX connector pins and their signals when the port is operating in either MDI or MDI-X configuration.
  • Page 51: Translated Safety And Emission Information

    Appendix B Translated Safety and Emission Information Important This appendix contains multiple-language translations for the safety statements in this guide. Wichtig Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog.
  • Page 52 Manufacturer Telephone: 408-730-0950 Declares that the product: Bridging Converter Model Numbers: AT-FS232, AT-FS232/1, AT-FS232/2, AT-FS232/3, AT-FS232/4 This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 53 AT-FS232 and AT-FS232/x Series Installation Guide Standards: This product meets the following standards: RFI Emission FCC Class B, EN55022 Class B, VCCI Class B, C-TICK Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
  • Page 54 Translated Safety and Emission Information Caution: “Safety Hazard” Check to see if there are any exposed copper strands coming from the installed wire. When this installation is done correctly there should be no exposed copper wire strands extending from the terminal block.
  • Page 55 AT-FS232 and AT-FS232/x Series Installation Guide Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. Hochfrequenzstörung FCC Klasse B, EN55022 Klasse B, VCCI Klasse B, C-TICK Warnung: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
  • Page 56 Translated Safety and Emission Information Vorsight: “Sicherheitsrisiko” Prüfen Sie, daß aus dem installierten Draht keine freiliegenden Kupferlitzen herausragen. Bei korrekter Installation sollten aus dem Anschlußklemmblock keine freiliegenden Kupferlitzen vorstehen. Freiliegende Kabel führen genug Spannung, um Personen zu gefährden, die diese Drähte berühren.
  • Page 57 AT-FS232 and AT-FS232/x Series Installation Guide Standarder: Dette produkt tilfredsstiller de følgende standarder. Radiofrekvens forstyrrelsesemission FCC Klasse B, EN55022 Klasse B, VCCI Klasse B, C-TICK Advarsel: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
  • Page 58 Translated Safety and Emission Information Forsiktig: “Fare” Se omhyggeligt efter om der stikker blanke kobbertråde ud fra klemmeforbindelserne. Ved korrekt montering er det ikke tilfældet. Enhver afisoleret leder kan lede farlig strømstyrke til personer, som kommer til at røre ved dem.
  • Page 59 AT-FS232 and AT-FS232/x Series Installation Guide Eisen: Dit product voldoet aan de volgende eisen. RFI Emissie FCC Klasse B, EN55022 Klasse B, VCCI Klasse B, C-TICK Waarschuwing: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
  • Page 60 Translated Safety and Emission Information Let Op: “Veiligheidsrisico” Controleer of er bij de aangesloten bedrading geen koper blootligt. Als de installatie juist is uitgevoerd, is er bij het aansluitblok geen koperdraad zichtbaar. Blootliggende bedrading kan schadelijke elektriciteitsniveaus geleiden naar personen die met de draden in aanraking komen.
  • Page 61 AT-FS232 and AT-FS232/x Series Installation Guide Normes: Ce produit est conforme aux normes de suivantes. Emission d'interférences radioélectriques FCC Classe B, EN55022 Classe B, VCCI Classe B, C-TICK Mise En Garde: Dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l'utilisateur devra prendre les mesures adéquates.
  • Page 62 Translated Safety and Emission Information Mise En Garde: Lors de l’installation de cet équipement, vérifiez toujours que la connexion de terre du châssis est installée en premier et débranchée en dernier. Attention: “Risque de sécurité” Vérifiez qu’aucun fil de cuivre dénudé ne sort du câble installé.
  • Page 63 AT-FS232 and AT-FS232/x Series Installation Guide Standardit: Tämä tuote on seuraavien standardien mukainen. Radioaaltojen häirintä FCC Luokka B, EN55022 Luokka B, VCCI Luokka B, C-TICK Varoitus: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä...
  • Page 64 Translated Safety and Emission Information Huomio: Turvallisuusriski Tarkista, ettei asennetusta johtimesta näy paljaita kuparisäikeitä. Kun asennus suoritetaan oikein, riviliittimestä ei pitäisi näkyä paljaita kuparijohdinsäikeitä. Paljaat johtimet voivat aiheuttaa sähköiskuvaaran, jos niihin kosketaan.
  • Page 65 AT-FS232 and AT-FS232/x Series Installation Guide Standard: Questo prodotto è conforme ai seguenti standard. Emissione RFI (interferenza di radiofrequenza) FCC Classe B, EN55022 Classe B, VCCI Classe B, C-TICK Avvertenza: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all'utente di prendere gli adeguati provvedimenti.
  • Page 66 Translated Safety and Emission Information Avvertenza: Quando si installa questo apparecchio, accertarsi sempre che il collegamento a massa del telaio sia sempre il primo ad essere effettuato e l’ultimo ad essere scollegato. Attenzione: “Pericolo!” Controllare che il filo installato non abbia trefoli in rame esposti.
  • Page 67 AT-FS232 and AT-FS232/x Series Installation Guide Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. RFI stråling FCC Klasse B, EN55022 Klasse B, VCCI Klasse B, C-TICK Advarsel: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
  • Page 68 Translated Safety and Emission Information Forsiktig: “Sikkerhetsfare” Kontroller om uisolerte koppertråder stikker ut av den monterte ledningen. Hvis monteringen er riktig utført, skal det ikke finnes uisolerte kobbertråder som stikker ut fra rekkeklemmen. Uisolerte ledninger kan lede skadelige mengder strøm til personer som berører ledningene.
  • Page 69 AT-FS232 and AT-FS232/x Series Installation Guide Padrões: Este produto atende aos seguintes padrões. Emissão De Interferência De Radiofrequência FCC Classe B, EN55022 Classe B, VCCI Classe B, C-TICK Aviso: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
  • Page 70 Translated Safety and Emission Information Atenção: “Perigo” Verifique se há algum fio de cobre exposto a sair do fio instalado. Quando esta instalação é feita correctamente não deve haver qualquer fio de cobre exposto a sair do terminal. Qualquer fio exposto pode conduzir níveis perigosos de electricidade para a pessoa que toque nos fios.
  • Page 71 AT-FS232 and AT-FS232/x Series Installation Guide Estándares: Este producto cumple con los siguientes estándares. Emisión RFI FCC Clase B, EN55022 Clase B, VCCI Clase B, C-TICK Advertencia: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
  • Page 72 Translated Safety and Emission Information Cuidado: “Riesgo de seguridad” Cerciórese de que no haya hilos de cobre pelados que salgan del alambre instalado. Cuando dicha instalación se realiza correctamente, los hilos de cobre pelados no deben salir del bloque terminal. Todo alambre pelado puede conducir niveles de electricidad nocivos a la persona que lo toca.
  • Page 73 AT-FS232 and AT-FS232/x Series Installation Guide Standarder: Denna produkt uppfyller följande standarder. Radiostörning FCC Klass B, EN55022 Klass B, VCCI Klass B, C-TICK Varning: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder.

This manual is also suitable for:

At-fs232/4At-fs232/1At-fs232/2At-fs232/3

Table of Contents