  • Page 1 AT-MC101 AT-MC102 Media Converters User’s Guide PN 613-10654-00 Rev A...
  • Page 2 Copyright ©1997 Allied Telesyn International Corp. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International Corp. Allied Telesyn International Corp. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice.
  • Page 3 An external 12 VDC power adapter supplies power to the media converters. The AT-MC101 has ST connectors; the AT-MC102 has SC connectors. See Figure 1 and Figure 2.
  • Page 4 AT-MC101 and AT-MC102 Media Converter 100Base-FX 100Base-TX MDI-X MC101 FAST ETHERNET MEDIA CONVERTER Figure 1: AT-MC101 Media Converter 100Base-FX 100Base-TX MDI-X MC102 FAST ETHERNET MEDIA CONVERTER Figure 2: AT-MC102 Media Converter...
  • Page 5 AT-MC101 and AT-MC102 User’s Guide Configuration Figure 3 shows two typical network configurations of the AT-MC101 or AT-MC102 Media Converter. Twisted Pair MC101 Media Converter 100Base-TX 3724TR Switch Fiber Optics 100Base-FX Workstation Fiber 100Base-FX MC101 Media Converter 2 kilometers 3724TR Switch...
  • Page 6: Mdi/Mdi-X Switch

    AT-MC101 and AT-MC102 Media Converter Major Features Full duplex transparent operation Low power consumption Minimal delay for optimum performance Fast data conversion Polyswitched fuse protection MDI/MDI-X switch Link and Receive LEDs on each port Power LED External power adapter MDI/MDI-X Switch The MDI/MDI-X switch located on the front of the unit, is a straight-through or crossover cable selection switch.
  • Page 7 Indicates valid data is being received Power Requirements The AT-MC101 and AT-MC102 draws power from the wall-mount external AC-DC power adapter attached to its DC jack. ATI supplies an approved safety compliant AC power adapter for the 120 and 240 VAC versions with an unregulated output of 12 VDC at 1A.
  • Page 8: Technical Specifications

    5% to 80% (noncondensing) EMI/RFI meets FCC Class A, IC Class A, EN55022 Class A Safety EN60825 EN60950 Immunity EN50082-1 Immunity Standard Warranty The AT-MC101 and AT-MC102 Media Converters have a lifetime warranty. The power adapter has a one year warranty.
  • Page 9: Where To Find Us

    AT-MC101 and AT-MC102 User’s Guide Where To Find Us For Technical Support or Service Location Phone Americas 1 (800) 428-4835 1 (206) 481-3790 United States, Canada, Mexico, Central America, South America Asia (+65) 3815-613 (+65) 3833-830 Singapore, Taiwan, Thailand, Malaysia,...
  • Page 10 Where To Find Us For Sales Information San Diego, CA Australia Tel: (619) 279-3899, Fax: (619) 279-3897 Lindfield, NSW Santa Ana, CA Tel: (612) 416-0619, Fax: (612) 416-9764 Tel: (714) 838-0434, Fax: (714) 838-9721 Canada Clearwater, FL Rexdale, Ontario Tel: (813) 726-0022, Fax: (813) 726-0234 Tel: (416) 675-6738, Fax: (416) 675-0057 Norcross, GA Richmond, British Columbia...
  • Page 11: Electrical Safety And Installation Requirements

    Electrical Safety and Installation Requirements STANDARDS: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 12 Electrical Safety and Installation Requirements Warning Do not stare into the Laser beam.electrical symbol LIGHTNING DANGER DANGER: DO NOT WORK on equipment or CABLES during periods of LIGHTNING ACTIVITY. DO NOT BLOCK AIR VENTS Do not connect a telephone line into the signal connector. OPERATING TEMPERATURE This product is designed for a maximum ambient temperature of 40 degrees C.
  • Page 13 AT-MC101 and AT-MC102 User’s Guide STANDARDER : Dette produkt tilfredsstiller de følgende standarder. Radiofrekvens forstyrrelsesemission EN55022 Klasse A ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger. Immunitet...
  • Page 14 Electrical Safety and Installation Requirements Sluit geen telefoonlijn aan op de signaalverbinding. BEDRIJFSTEMPERATUUR De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius. ALLE LANDEN: het toestel installeren overeenkomstig de lokale en nationale elektrische voorschriften. NORMES: ce produit est conforme aux normes de suivantes. Emission d’interférences radioélectriques EN55022 Classe A MISE EN GARDE: dans un environnement domestique, ce produit peut provoquer des...
  • Page 15 AT-MC101 and AT-MC102 User’s Guide Tähtipisteeseen (hub) syötettävän virran pitää tulla ainoastaan sovittimesta. EUROPE - EC Käytä TÜV-lisenssillä valmistettua verkkosovitinta, jonka tasajännitteen nimellisarvot ovat 12V dc, 500mA (milliampeeria). Tämä on “ENSIMMÄISEN LUOKAN VALODIODITUOTE” VARIOTUS Älä katso säteeseen. SALAMANISKUVAARA HENGENVAARA: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA SALAMOINNIN AIKANA.
  • Page 16 Electrical Safety and Installation Requirements SIKKERHETSNORMER: Dette produktet tilfredsstiller følgende sikkerhetsnormer. RFI stråling EN55022 Klasse A ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren tade nødvendige forholdsregler. Immunitet E N50082-1 Laser EN60825 SIKKERHET All strømtilførsel må...
  • Page 17 AT-MC101 and AT-MC102 User’s Guide PERIGO DE CHOQUE CAUSADO POR RAIO PERIGO: NÃO TRABALHE no equipamento ou nos CABOS durante períodos suscetíveis a QUEDAS DE RAIO. NÃO BLOQUEIE AS ABERTURAS DE VENTILAÇÃO Não conecte uma linha telefônica ao conector de sinal.
  • Page 18 Electrical Safety and Installation Requirements STANDARDER: Denna produkt uppfyller följande standarder. Radiostörning EN55022 Klass A VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. Immunitet EN50082-1 Laser EN60825 SÄKERHET Endast anslutningsenheten får vara kraftkälla till centralen. EUROPE - EC Använd en växelströmsanslutningsenhet licensierad av TÜV.