6. Operation
Attention should be paid that there is a connection between GND and
cable shield as well as the connector housing in the adapter cable. At
brass probes this is also connected to GND. Possibly an isolated
installation of the probe is necessary to prevent an unintended
connection between measuring GND and protective earth.
6.6.4

Usage of the AS-Adapter 3

There are three connections to use the AS-Adapter3.
First, the AS active probes are connected to the "± 3V" and "IN X", "IN Y",
"IN Z" terminals of the AS adapter 3 using the 3 enclosed adapter cables.
For pin assignment of the adapter cable, see table 2 on page 80.
For power supply, the input "Power" is connected to a voltage source, which
provides a DC voltage between 9 V and 36 V.
Third, the outputs "OUTX", "OUTY", "OUTX" are connected to the analog
input of a measuring transducer, such as a PLC or connected to an
oscilloscope.
The gain switch is moved to the desired position (x5 or x50).
On the following pages 83 and 84 2 different connection options are shown.