TABLE 11: RS-232 MENU ITEM DEFINITION

Item
S/N
Serial Number of the unit
Version number of the main controller board software within the SSPB that
Soft
is connected to the RS-232 port of the PC
Unit Pos
Indicates the position of the unit (A, S or B) in the redundant system
Name
Indicates the name of the unit
MAC
Indicates the serial address of the Monitor and Control of the unit (in hex)
Current
Indicates the 12 VDC current consumption of the unit, in amperes
TxF Shift
Indicates the LO Frequency of the unit transmission path, in MHz
Indicates the Forward Power of the unit (the transmission path output
FPWR
power) in dBm
TxGain
Indicates the transmission Gain in dB
Tx Stat
Indicates the transmission status (On or Mute)
Indicates the Reverse (reflected) Power of the unit (the transmission path
RPWR
reflected power) in dBm
Hot Spot Temperature of the driver, followed by hot spot temperature of the
Temp HS
Power Module (HPA) in degrees Celsius.
PS
Power Supply voltage in V
Alarms
Provides the fault messages and the normal status message:
1. Alarm (excess +12 VDC current, faulty RF devices, power supply
2. Out of Lock of the PLL in Up-Converter shutdown
3. High Reflected Power shutdown
4. Overdrive Alarm (output power exceeds by 1.5 dB the rated P1dB)
5. Temperature shutdown (ambient temperature exceeds 85ºC).
6. OK (SSPB unit is functioning properly).
SW1
Switch1 Position (On Line, Stand By, N/C when not connected, error if
switch failed) or N/A if the switch is not driven by this unit
SW2
Switch2 Position (On Line, Stand By, N/C when not connected, error if
switch failed) or N/A if the switch is not driven by this unit
SW3
Switch3 Position (On Line, Stand By, N/C when not connected, error if
switch failed) or N/A if the switch is not driven by this unit
POS
Position of unit S (A, or B) or N/A for units A and B
Redundant
Internal communication between units in a redundant system. Will always
be NoComm (no communication) for these units
failure, L-RF up-converter module failure).