10/100/1000base-t to sfp (mini-gbic) type fiber optic media converter; 10/100/1000base-t to 1000base-sx sc type fiber optic media converter; 10/100/1000base-t to 1000base-lx sc type fiber optic media converter (32 pages)
4k hevc/h.264 real-time encoder box with 12g-sdi/hdmi (27 pages)
Summary of Contents for Advantech SSPBMg–C200–BRE
Page 1
INSTALLATION AND OPERATING MANUAL 200W C-Band Hub-mount SOLID STATE POWER BLOCK UP-CONVERTER (SSPB) SSPBMg–C200–BRE PM GR0-3161A0-3N0R, Rev. 5...
Page 2
This Advantech Wireless product is warranted against defects in material and workmanship for a period of 2 years from date of shipment. During the warranty period, Advantech Wireless will, at its option, either repair or replace products that will prove to be defective.
Page 4
SSPBMg-C200-BRE MAINTENANCE......................23 PREVENTIVE MAINTENANCE.................23 6.1.1 Mechanical Preventive Maintenance .................23 6.1.2 Checking the Cooling Fans..................23 RS-232 SERIAL COMMUNICATION .................24 HAND-HELD TERMINAL ..................24 RS-232 PC TERMINAL....................26 RS-485 SERIAL COMMUNICATION .................34 PACKING LIST.......................35 SAFETY AND EMC COMPLIANCE ................36 APPENDIX A: RS-485 SERIAL COMMUNICATION PROTOCOL.......37 11.1 INTRODUCTION ......................37 11.2...
Page 5
SSPBMg-C200-BRE FIGURES 1: P ...................... 11 IGURE RODUCT UTLINE 2: B ......................12 IGURE LOCK IAGRAM 3: C ....................... 15 IGURE ONNECTORS 4: H HELP M ................24 IGURE HELD ERMINAL 5: H STATUS M ..............25 IGURE HELD ERMINAL 6: H RS-232 C –...
Page 6
SSPBMg-C200-BRE TABLES TABLE 1: ELECTRICAL SPECIFICATIONS................13 TABLE 2: MECHANICAL SPECIFICATIONS ................ 14 TABLE 3: POWER REQUIREMENTS ..................14 TABLE 4: ENVIRONMENTAL CONDITIONS................ 14 TABLE 5: CONNECTORS ......................16 TABLE 6: AC LINE (J5) – PIN ASSIGNMENTS..............16 TABLE 7: SYSTEM CONTROL (RS232 RS485) – PIN ASSIGNMENTS ......20 TABLE 8: SERIAL INTERFACE RS-232 CONNECTION INFORMATION......
PERSONNEL WORKING ON RADIO TRANSMITTING EQUIPMENT’, also Sub-clauses 3.2, 3.7 and 22.1 of the Standard. To prevent the risk of personal injury or loss related to equipment malfunction Advantech Wireless uses the following symbols for safety related information. For your own safety, please read the information carefully BEFORE operating the equipment.
Page 8
The maximum permissible levels of exposure are quite low in comparison to the power levels produced by the equipment built by Advantech Wireless (e.g. less than 10 mW versus 4 to 700 W delivered by the different units). The maximum permissible levels are currently being studied by a number of organizations.
For a safe and versatile operation, please read the information carefully BEFORE using the equipment. Advantech Wireless has prepared this manual for use as a guide for the proper installation, operation and maintenance of Advantech Wireless equipment and computer programs. The drawings, specifications and information contained herein are the property of Advantech Wireless.
SSPBMg-C200-BRE 2.2.2 U ONVERTER SSEMBLY The L-Band signal arriving from a modem enters the Up-Converter Assembly through a ‘N-type’ connector, see Figure 3: Connectors (page 15). The L-Band signal (950 MHz to 1525 MHz) enters the high gain Low Noise Amplifier (LNA) and Medium Power Amplifier (MPA) stages that boost the RF power level sufficient for the transmission through the Up- Converter Assembly.
SSPBMg-C200-BRE 2.2.4 HPA A SSEMBLY The HPA Assembly amplifies the RF signal from the Up-Converter Assembly to a power level sufficient for transmission. Integral to this module are three HPA stages and a power conditioner board. Other functionality includes internal power conditioning and overtemperature shutdown. 2.2.5 C ONTROLLER OARD...
SSPBMg-C200-BRE +45 V +12 V REDUND LEDS MUTE FAULT SHUT-DOWN_MON FWPWR C (temp info) -9 V TERM -9 V FWPWR SD_MON FAULT MUTE RS485 RS232 + 5 V -9 V +12 V +12 V (VAR) +12 V (VAR) +12V Figure 2: Block Diagram Page 12...
SSPBMg-C200-BRE 2.3 SSPB SPECIFICATIONS TABLE 1: ELECTRICAL SPECIFICATIONS L-Band Input Frequency 950 – 1525 MHz RF Output Frequency Range 5.850 – 6.425 GHz Frequency Stability Based upon 10 MHz Internal Reference RF Saturated Output Power (P + 53 dBm, typical (200 W) Linear Output Power (P + 50.0 dBm, min Linear Gain...
SSPBMg-C200-BRE TABLE 2: MECHANICAL SPECIFICATIONS Physical Dimensions See Figure 1: Product Outline (page 11) – white paint Approximate Weight 24.25 lbs (11 kg) Mounting holes (4) 1/4-20, 0.40” (6 places) and #10-32 0.250” (6.35 mm) deep (4 places both sides), see Figure 1: Product Outline (page 11) TABLE 3: POWER REQUIREMENTS Power Requirements 90 to 264 V AC (110 / 220 V AC autoranging)
SSPBMg-C200-BRE TABLE 5: CONNECTORS Connector Function Description Mating Connector L-Band IN (J1) N-Type (F) N-Type (M) (Up-converter Input) M&C Serial Interfaces (J2) MS 3112E12-10P (M) MS 3116G12-10S (F) RS-485 & RS-232 (J3) (not available for Relay Interface MS3112E10-6P (M) MS3116F10-6S (F) these units) AC Supply (J5) AC LINE...
SSPBMg-C200-BRE 3. UNPACKING AND INSTALLATION This Section contains instructions for the site preparation, unpacking and the installation of an SSPB. 3.1 INITIAL INSPECTION Inspect the shipping container for damage. If the container or cushioning material is damaged, immediately contact the carrier that delivered the equipment and submit a damage report. Failure to do so could invalidate all future claims.
The centre pins of the connectors used by Advantech Wireless have a precision tolerance measured in mils (1/1000 inch). The mating connectors of the various suppliers may not be of precision types.
SSPBMg-C200-BRE 3.3.4 C OOLING ONSIDERATIONS The SSPB is forced-air cooled. The cooling fans are configured for 12 V DC operation, supplied by the main power supply of the unit. Depending on environmental conditions, the airflow opening may become obstructed by debris, reducing the efficiency of the cooling system. NOTE: The cooling fans rotation speed is temperature dependent.
SSPBMg-C200-BRE 4. INTERFACES 4.1 SYSTEM CONTROL CONNECTOR (RS-485 RS-232) The System Control interface connector is located at port (RS232 RS485) of the SSPB. This is a 10-pin MS3112E12-10P (male) connector with pin assignments as shown in TABLE 7 below. Both RS-485 and RS-232 serial interfaces are for the serial interface communication link, allowing for the external monitoring and control of the SSPB.
SSPBMg-C200-BRE 4.2 REDUNDANT INTERFACE NOTE: This connector is not installed on these units and consequently this interface is not available. The Redundant Interface connections are made with a 10-pin circular connector mounted on the SSPB enclosure. The connector type is listed in TABLE 5 at page 16 and the location is shown in Figure 3 at page 15.
SSPBMg-C200-BRE 5. PRE POWER AND CHECKOUT This Section contains the pre-power and checkout procedure for the SSPB model SSPBMg-C200-BRE. WARNING! The information presented in this Section is addressed to the technicians who have specific training in, and knowledge of the Microwave Power Transmitters. Inappropriate use of an SSPB may cause serious injury to the operator or damage to the equipment.
SSPBMg-C200-BRE 6. MAINTENANCE This Section describes the scheduled maintenance procedure for the SSPB. CAUTION! Improper maintenance of the SSPB may void the warranty. 6.1 PREVENTIVE MAINTENANCE This product requires minimum maintenance, which consists of visual inspection and cleaning. WARNING! Personnel performing maintenance on this system must have the proper training and become thoroughly familiar with the related safety requirements and issues.
SSPBMg-C200-BRE 7. RS-232 SERIAL COMMUNICATION 7.1 HAND-HELD TERMINAL W a t t C - B a n d S S P B > ENTER ENTER ENTER ENTER L I S T C O M M A N D S S T A D i s p l a y s t a t u s S e t...
SSPBMg-C200-BRE 7.2 RS-232 PC TERMINAL For RS-232 VT communication, use the following communication parameters: - Bits per second: 9600 - Data Bits: 8 - Parity: None - Stop bits: 1 - Flow Control: None TABLE 8: SERIAL INTERFACE RS-232 CONNECTION INFORMATION RS-232 at PC Pin Serial Interface Active Condition...
SSPBMg-C200-BRE Figure 11: HyperTerminal RS-232 Communication – “help baud” and “baud rs232” commands and responses NOTE: The baud rate may be set only f or RS-232 seria l interface (to 9600 or to 19200 bauds). fter re-setting the baud rate, the communication program used (HyperTerminal or other VT ommunication programs) must be set for the new baud rate.
SSPBMg-C200-BRE Figure 12: HyperTerminal RS-232 Communication – “help rs485”, “rs485 ascii” and “rs485 binary” commands and responses OTE: The rs485 parameter may be set to ascii, to binary, or to skywan. When this parameter is set to ascii, the RS-485 serial interface will work as a VT serial interface (the same windows as for RS-232 serial interface will be available on RS-485 interface).
SSPBMg-C200-BRE 8. RS-48 5 SERIAL COMMUNICATION he RS-485 serial communication is based on the protocol in 11 APPENDIX A: RS-485 SERIAL COMMUNICATION PROTOCOL at page 37. Note that in order to connect the RS-485 of the unit to the RS-232 interface of a PC an adequate RS-485/RS-232 adapter should be used.
SSPBMg-C200-BRE 10. SAFETY AND EMC COMPLIANCE Advantech Wireles s products are compliant with the following standards: SAFETY: IE 0950 -1 second edition 2005 MC: EN301489-1 2004 (EMC for radio equipm ent and services, common technical requirements) EN 5022: 1998 / A1: 2000 - Class A EN61000-4-4 Transient/burst 0.5kV Signal Lines, 1 kV Power Lines...
0x55. After this start byte, each frame consists of 7 bytes. Firs t byte: ter (NMS) to Slave (Advantech Wireless unit): Address of correspo ndent Advantech Wireless unit (0x01 to 0x0F). Slave to Master: When Advantech Wireless unit sends the respond frame to NMS, it left shifts its unit address by 4.
SSPBMg-C200-BRE 11.3 COMMANDS These commands go only from master-slave direction. TABLE 10: COMMANDS Respond. 2,3,4,5,6 Description 2nd byte 3, 4, 5 &6 bytes bytes Request condition 0x01 or 0xAA AA AA AA See TABLE 11 status 0x2A Mute/Unmute 0x5A AA AA AA To mute 0x02 See TABLE 11 command...
Page 40
SSPBMg-C200-BRE TABLE 10: COMMANDS (continued) Respond. 2,3,4,5,6 Description 2nd byte 3, 4, 5 &6 bytes bytes. Byte 2, Read Hot Spot 0x12 0xAA AA AA AA Temperature temperature Byte 4,5,6: 0xAA Set operation m 0x5A– On (Auto) 0x1F See TABLE 11 (Set Switch M ode) 0xA5–...
SSPBMg-C200-BRE 11.4 RESPONSES TO COMMANDS FROM SLAVE TO MASTER 11.4.1 C ONDITION TA TUS ESPONSE TABLE 11: COND ITION STATUS RESPONSE Bit No 2nd byte 3rd byte byte 5 byte byte Status 1-on, 0-off 1- Sum Alarm Output le Output level 0x00 byte LS byte...
SSPBMg-C200-BRE 11.4.3 R GAIN/ATTENUATION R ANGE ESPONSE TABLE 13: READ GAIN/ATTENUATION RANGE RESPONSE Bit No byte byte byte byte byte MS byte LS byte MS byte LS byte minimum minimum maxi m imum 0x5A value value value 11.4.4 R TATUS ESPONSE TABLE 14: READ UNIT STATUS RESPONSE Bit No...
SSPBMg-C200-BRE 12. APPENDIX B: RS-485 SKYWAN SERIAL COMMUNICATION ROTOCOL For rem ote operation, the SSPB is equipped with a monitor and control function. Th e M&C function contains all of the relevant data concerning the control and status signals of th e SSPB.
SSPBMg-C200-BRE 12.3.1 T RANSMISSION NTERFACE A request packet (see TABLE ) is sent by the IDU and the respective response packet (see TABLE ) by the SSPB. The IDU is the bus master. The SSPB is only allowed to respond if the first byte of the request packet matches its address and the checksum is consistent.
SSPBMg-C200-BRE 12.3.2 C (IDU SSPB) OMMAND ESSAGE TRUCTURE TABLE 15: COMMAND MESSAGE STRUCTURE Byte Name Description Value Address Address of SSPB 0x01 to 0x0F Command Request Status 0x01 Transmit ON/OFF 0x02 Change Address 0x03 Set Input Frequency 0x04 Not applicable for these units Not applicable for these units Data Byte 1 Not used if command = 0x01 0xAA...
SSPBMg-C200-BRE 12.3.3 R (SSPB IDU) ESPONSE ESSAGE TRUCTURE TABLE 16: RESPONSE MESSAGE STRUCTURE Byte Name Description Value dress Address of SSPB shifted left by 4 0x10 to 0x Level Byte 1 MS byte of T x output power Level Byte 2 LS byte of Tx output power Temperature Hot Spot Tem...