80 w ku-band hub-mount solid state power block up-converter (sspb)
Table of Contents

Advertisement

Quick Links

INSTALLATION AND OPERATING MANUAL
80 W K
-BAND HUB-MOUNT
U
SOLID STATE POWER BLOCK UP-CONVERTER (SSPB)
SSPBM – K80 – BTE
PM 1R0-83A1A0-2N0, Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Advantech SSPBM-K80-BTE

  • Page 1 INSTALLATION AND OPERATING MANUAL 80 W K -BAND HUB-MOUNT SOLID STATE POWER BLOCK UP-CONVERTER (SSPB) SSPBM – K80 – BTE PM 1R0-83A1A0-2N0, Rev. 1...
  • Page 2 LIMITATIONS OF WARRANTY ADVANTECH Advanced Microwave Technologies, Inc. warrants this product to be free of materials and workmanship defects. The foregoing warranty shall not apply to defects resulting from improper handling or abuse by the Buyer, unauthorized modification, operation outside of the environmental specifications for the product, or improper installation or maintenance.
  • Page 3: Table Of Contents

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE CONTENTS SAFETY ......................... 6 GENERAL INFORMATION .................. 9 INTRODUCTION ..........................9 DESCRIPTION ..........................9 2.2.1 Power Supply ..........................9 2.2.2 Up-Converter Assembly ......................10 2.2.3 RF Driver Module........................10 RF High Power Module......................10 2.2.4 2.2.5 Waveguide Arm Assembly .......................
  • Page 4 Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE OPERATION......................26 INTRODUCTION .......................... 26 SAFETY CONSIDERATIONS......................26 BASIC OPERATING PROCEDURE ....................26 USING THE SSPB SOFTWARE ..................... 27 6.4.1 Using the RS-232 Interface....................... 27 6.4.2 Using the RS-485 Interface....................... 33 MAINTENANCE....................34 PREVENTIVE MAINTENANCE ....................34 7.1.1 Mechanical Preventive Maintenance..................
  • Page 5 Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE FIGURES 1: P ....................... 12 IGURE RODUCT UTLINE 2: B ......................13 IGURE LOCK IAGRAM 3: C ....................... 16 IGURE ONNECTORS 4: T ................... 28 IGURE ERMINAL ISPLAY 5: L ... 30 IGURE IST OF COMMANDS AFTER PRESSING H ERMINAL ISPLAY...
  • Page 6 Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE TABLES TABLE 1: ELECTRICAL SPECIFICATIONS ................14 TABLE 2: MECHANICAL SPECIFICATIONS ................. 15 TABLE 3: POWER REQUIREMENTS..................15 TABLE 4: ENVIRONMENTAL CONDITIONS ................ 15 TABLE 5: CONNECTORS......................16 TABLE 6: AC LINE (J5) – PIN ASSIGNMENTS ............... 17 TABLE 7: RELAY INTERFACE –...
  • Page 7: Safety

    PERSONNEL WORKING ON RADIO TRANSMITTING EQUIPMENT’, also Sub-clauses 3.2, 3.7 and 22.1 of the Standard. To prevent the risk of personal injury or loss related to equipment malfunction Advantech uses the following symbols for safety related information. For your own safety, please read the information carefully BEFORE operating the equipment.
  • Page 8 Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE ----------------------------------------------- WARNING --------------------------------------------------- hen supplying power to this equipment, use the 3-pin connector provided to connect to a grounded power outlet; also use a ground strap between the station’s ground bus and the ground screw located on unit. If power is supplied without grounding the equipment, there is a risk of receiving a severe or fatal electric shock.
  • Page 9 The permissible levels of exposure are quite low in comparison to the power levels of the equipment built by Advantech (e.g. less than 10 mW versus 4 to 700 W delivered by different units). The permissible levels are currently being studied by a number of organizations. In the past the U.S.
  • Page 10: General Information

    Technologies, Inc. 2.2 DESCRIPTION The SSPBM-K80-BTE is a 80 W Ku-Band hub-mount (outdoor) Solid State Power Block Up- Converter (SSPB). The entire SSPB is self-contained and is intended for mounting near the hub of the antenna. It incorporates DC main power supply and forced air-cooling system, see Figure 1: Product Outline (page 12).
  • Page 11: Up-Converter Assembly

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 2.2.2 U ONVERTER SSEMBLY The Up-Converter converts the input L-Band carrier into a Ku-Band carrier. The 950 – 1450 MHz L-Band input signals are fed at the input co-axial interface connector. A block up-converter using a low phase noise RF oscillator, which is phase locked to the 10 MHz internal reference, translates the 950 - 1450 MHz L-Band frequency-range to 14.000 - 14.500 GHz Ku-Band frequencies.
  • Page 12: Packing List

    Item Quantity Description Part # PM 1R0-83A1A0-2N0 Rev. 1 Installation and Operating Manual Ku-Band 80 W SSPB, 1R0-83A1A0-2N0 model SSPBM-K80-BTE Connector Circular MIL C-5015, Straight Cable Plug 3 Sockets 631-310620-002 MS3106F20-19S (Connector for AC LINE connector J5) Connector circular, MIL-C-26482, 6...
  • Page 13 Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE Figure 1: Product Outline Page 12...
  • Page 14 Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE RS-485_PM +12 V RS-485_PM ALM_PA RS-485_PA MUTE_PA ALM_PA +12 V RS-485_PA MUTE_PA +12 V ALM_DR RS-485_DR ALM_L-RF ALM_DR RS-485_L-RF RS-485_DR CURR +12 V +12 V +12V ALM_L-RF RS-485_L-RF +12 V Figure 2: Block Diagram Page 13...
  • Page 15: Sspb Specifications

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 2.4 SSPB SPECIFICATIONS The SSPB specified herein is capable of meeting exceeding the performance specifications listed in the following table over frequency range, operating temperature and line voltage variation unless otherwise specified. The SSPB will meet all RF performance specifications within thirty minutes of application of prime power.
  • Page 16: Table 2: Mechanical Specifications

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE TABLE 2: MECHANICAL SPECIFICATIONS Physical Dimensions See Figure 1: Product Outline (page 12) Approximate Weight 50 kg (110 lbs) Mounting holes (6) 0.40” (10 mm) dia., see Figure 1: Product Outline (page 12) TABLE 3: POWER REQUIREMENTS Power Requirements 198-264 V AC, 47-63 Hz, single phase Power Consumption...
  • Page 17: Table 5: Connectors

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE Fig e 3: Connectors TABLE 5 : CONNECTORS Connector Function Description Mating Connector N - Type (F) 50 Ω N - Type (M) 50 Ω Up-converter Input TX In RS 232 Serial Interface MS3112E10-6P (M) MS3116F10-6S (F) N - Type (F) 50 Ω...
  • Page 18: Table 6: Ac Line (J5) - Pin Assignments

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE TABLE 6: AC LINE (J5) – PIN ASSIGNMENTS Description PHASE (LIVE) GROUND NEUTRAL Page 17...
  • Page 19: Interfaces

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 3. INTERFACES Each unit provide s four interfaces that can be used to connect the unit to several optional external devices. The interfaces for this model are listed b elow: 1. Relay (Discrete) Interface: This interface offers the essential monitoring and control of the unit by discrete signals.
  • Page 20: Table 7: Relay Interface - Pin Assignment

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE TABLE 7: RELAY INTERFACE – PIN ASSIGNMENT Signal Name Description ormal closed contact of the Tx ALARM Form - C relay. Tx AL-NC Pin A closed to pin B indicates ALARM in the transmission path. Tx AL-COM Common contact of the Tx ALARM...
  • Page 21: Rs-232 Interface

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 3.2 RS-232 INTERFACE his serial communication interface offers to the operator the essential monitoring and control of the unit, using any PC terminal software. An IBM compatible personal com puter can be connected to this port. The interface uses a 6-pin circular connector mounted on the Up- Converter connector plate.
  • Page 22: Rs-485 Interface

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 3.3 RS-485 INTERFACE This serial communication interface provides access to all monitor and control functions for the SSPB Up-Converter. The RS-485 interface in a redundant system must be connected to the Network Management System (NMS). The NMS will have access to both units, discriminating them by address. The interface uses a 6-pin circular connector mounted on the unit enclosure.
  • Page 23: Unpacking And Installation

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 4. UNPACKING AND INSTALLATION This section contains instructions for site preparation, unpacking and installation of the SSPB. This section contains instructions for site preparation, unpacking and installation of the SSPB. 4.1 INITIAL INSPECTION 4.1 INITIAL INSPECTION Inspect the shipping container for damage.
  • Page 24: Electrical Connections

    RF component connector. A destructive pin depth is one that is too long in respect to th reference plane of the connector. The center pin of the connectors used by ADVANTECH has precision tolerance measured in mils (1/1000 i nch).
  • Page 25: Cooling Considerations

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE • RF output (J7) WR–75 waveguide flange (flat), see Figure 1: Product Outline (page 12). User needs WR–75 waveguide flange, grooved. NOTE: Wrap the mastic tape (provided in the shipping kit) around all connectors in order to prevent water/humidity ingress and resultant damage.
  • Page 26: Initial Power On And Checkout

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 5. INITIAL POWER ON AND CHECKOUT This section describes the procedure for turning on the SSPB for the first time. It also describes the steps for initial checkout of the system. Before proceeding with the steps in this section, read it comp tely to become familiar with normal operation of the SSPB.
  • Page 27: Operation

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 6. OPERATION 6.1 INTRODUCTION This Section describes the normal operation of the Up-Converter. The design of this equipment llows for minimal operator intervention and maintenance. he unit may be monitored and controlled via the RS-232 or the RS-485 serial interfaces, or via e Relay interface.
  • Page 28: Using The Sspb Software

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 5. Ensure that the L-Band input signal is being applied to the Tx Input connector. 6. Allow the unit to warm up for 30 minutes, ensuring that all electrical specifications are met (see TABLE 1 at page 14).
  • Page 29 Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE Figure 4: Terminal Mode Display Page 28...
  • Page 30: Table 11: Rs-232 Menu Item Definition

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE TABLE 11: RS-232 MENU ITEM DEFINITION Item Description Serial Number of the unit Version number of the main controller board software within the SSPB that Soft is connected to the RS-232 port of the PC Unit Pos Indicates the position of the unit (A, S or B) in the redundant system Name...
  • Page 31 Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE Figure 5: L ist of commands (after pressing h- Help) in Terminal Mode Display Page 30...
  • Page 32: Table 12: Computer Terminal Commands For Rs-232 Interface

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE NOTE: All shadowed lines in the following table are for commands not applicable for these nits TABLE 12: COMPUTER TERMINAL COMMANDS FOR RS-232 INTERFACE Command Description Response Provides the list of commands that can be used to Help function modify the status of a unit.
  • Page 33 Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE TABLE 12: COMPUTER TERMINAL COMMANDS FOR RS-232 INTERFACE (continued) Command Description Response Command to switch to Hand Held Terminal (this is Small term e default mode; the unit will start in this mode) ommand to switch to PC Terminal. If connected to a Big term C, always type t2 to achieve connection to PC, ecause the default mode is...
  • Page 34: Using The Rs-485 Interface

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 6.4.2 U RS-485 I SING THE NTERFACE In order to use this interface, refer to Section 8 APPENDIX A: RS-485 SERIAL COMMUNICATION PROTOCOL. Page 33...
  • Page 35: Maintenance

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 7. MAINTENANCE This section describes scheduled maintenance procedure for SSPB. CAUTION: Improper maintenance of the SSPB may void the warranty. 7.1 PREVENTIVE MAINTENANCE This product requires minimum maintenance. This consists of visual inspection and cleaning. WARNING: The person performing maintenance of this equipment must have training and knowledge of the product, safety requirements and safety issues related to the equipment.
  • Page 36: Table 13: Module Replacement

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE TABLE 13: MODULE REPLACEMENT Module Description Part Number 80W Ku-Band Power Module (A1) 200-03A000-201 1500 W P/S 220V/12VPower Supply Assembly (A2, A3) 27T-000000-211 Main Controller Board (A4) 210-250397-002 L-Band to Ku-Band Up-Converter Module (A5) 200-230100-131 Digital Power Monitor (A7) 210-400464-003 24W Ku-Band Driver Module (A9)
  • Page 37: Appendix A: Rs-485 Serial Communication Protocol

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 8. APPENDIX A: RS-485 SERIAL COMMUNICATION PROTOCOL The protocol described in this Section is used for the interconnection between the SSPB Up- Converter unit and the user’s monitoring and control system. The protocol supports the 4-wire RS-485 inter face using the communication set-up 9600.N.8.1.
  • Page 38: Table 14: Command Frame Structure

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE TABLE 14: COMMAND FRAME STRUCTURE Response: 2 , 3 , 4 , & 6 bytes Description byte & 6 bytes 0x5A– mute Tx, Mute/Un-Mute Command 0x02 See TABLE 15 0xA5 – un-mute Tx 0x5A XX XX XX for A Set Gain 0x05 See TABLE 15...
  • Page 39: Responses To Commands From Slave To Master

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE 8.2 RESPONSES TO COMMANDS FROM SLAVE TO MASTER For command 15 (0x2A - request condition status) the response is given in the following table. TABLE 15: CO ON STATUS RESPO Bit No byte byte 4 byt byte 6 byte Tx status 1-...
  • Page 40: Table 16: Read Identification Response

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE For command 3 (0x07 – read identification) the response is given in the following table: T ABLE 16: READ IDENTIFICATION RESPONSE byte byte byte byte byte 1 – Up 1 – ALC On 0 – ALC Off 1 –...
  • Page 41: Table 18: Read Gain Range Response

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE For command 7 (0x0D – read gain range) the response is given in the following table: TABLE 18: READ GAIN RANGE RESPONSE 2 byte byte byte byte byte MS by LS byte MS byte LS byte Minimu Minimum 0x5A for Tx...
  • Page 42: Table 20: Read Frequency Shift Response

    Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE For command 14 (0x27 – read frequency shift) the response is given in the following table: BLE 20: READ FREQUENCY SHIFT RESPONS byte byte byte byte byte MS byte LS byte 0x5A for A 0xAA 0xAA Frequency Frequency...
  • Page 43 Advanced Microwave Technologies DVANTECH SSPBM-K100-BTE ure 6: P ropose d Graphic Us er Interfa (GUI) based on S-485 Protocol Page 42...
  • Page 44: Appendix B: Safety And Emc Compliance

    Technologies DVANTECH SSPBM-K100-BTE 9. APPENDIX B: SAFETY AND EMC COMPLIANCE Advantech Products are compliant with following standards: SAFETY: IEC 950 (1992) CAN/CSA-C22.2 No. 950 –92/ UL 1950 EMC: EN 55022: 1995 / CISPR22:1993 – Class A Conducted and Radiated Emission.