VENTILATION
REQUIREMENTS
STEP 2:
A suitable
exhaust
hood must be installed
above the cooktop.
The following
chart indicates
the
minimum
blower capacity recommended
for hood ventilation.
VENTILATION
STANDARD COUNTER
ISLAND
UNIT
INSTALLATION
INSTALLATION
RECOMMENDATIONS
RECOMMENDATIONS
HOOD
(24" Deep x Unit Width)
(30" Deep x 36" at Bottom)
BLOWER
*48" COOKTOP
800-1200 CFM
800-1200 CFM
**36"
COOKTOP
600-800 CFM
600-1200 CFM
x When installing
a unit featuring
a grill, select a blower on the high end of recommendation.
__ For aii 36"Cooktop
GL models a 1200 CFM ventilation
unit is required.
CAUTION:
Ventilation
hoods and blowers are designed for use with single waft ducting.
However, some local building
codes or inspectors
may require
double
waft
ducting.
Consult local building
codes and/or local agencies, before starting,
to
ensure that hood and duct installation
wifl meet local requirements.
Hood
blower
speeds should
be variable
to reduce
noise and loss of heated
or air conditioned
household
air when maximum
ventilation
is not required.
Normally, the maximum
blower
speed is
only required when using the grill. For best smoke elimination,
the lower edge of the hood should be
installed a minimum
of 30" to a maximum
of 36" above the cooktop
cooking
surface, (step 3 pg. 8). if
the hood contains any combustible
materials (i.e. a wood covering) it must be a minimum
of 36" above
the cooking
surface.
Due to a high volume
of ventilation
air, a source of outside
replacement
air is
recommended.
This is particularly
important
for tightly
sealed and insulated
homes.
A reputable
heating and ventilating
contractor
should be consulted.