Table B.42: Summary Relay Alarm Output Specification
Item
Safety status
Connector type
Connector designation:
Contact Configuration
Contact Rating
Maximum Switching Current
Maximum Switching Voltage
Maximum Switching Power
Minimum Switching Load
B.8.8

Alarm Connector (TT1260/HWO/ALRM) [Option]

This is an optional card.
Table B.43: Relay Alarm Output Specification (TT1260/HWO/ALARM)
Item
Safety status
Connector type
Connector designation:
Contact Configuration
Contact Rating
Maximum Switching Current
Maximum Switching Voltage
Maximum Switching Power
Minimum Switching Load
B.9
Environmental
B.9.1
Conditions
Table B.44: Environmental Conditions
Operational
Temperature
Humidity
Cooling requirements
Handling/movement
Page B-26
Specification
SELV
9-way D-type female
ALARM
SPDT (Change-over)
All volt-free contacts, fully isolated.
1A at 24 V d.c.
1A at 50 V a.c.
1A
50 V d.c. / 30 V a.c.
24 W / 60 VA
0.1 mA, 100 mVdc
Specification
SELV
25-way D-type female
ALARM RELAY
SPDT (Change-over)
All volt-free contacts, fully isolated.
1 A at 24 V d.c.
1 A at 50 V a.c.
1 A
50 Vdc / 30 V a.c.
24 W / 60 VA
0.1 mA, 100 mV d.c.
Specification
0°C to +50°C ambient air temperature with free airflow
0% to 95% (non-condensing)
Convection cooling/free airflow
Fixed (non-mobile) use only