Siemens SIPROTEC 4 7UT6 Series Manual page 475

Differential protection
Table of Contents

Advertisement

Additional Specification L for Further System Interfaces (device rear port B)
(only if Pos. 11 = 9)
Modbus, optical, 820 nm, ST connector
DNP3.0, RS485
DNP3.0, optical, 820 nm, ST connector
IEC 61850, 100 Mbit Ethernet, double electrical, RJ45 connector
IEC 61850, 100 Mbit Ethernet, optical, duplex LC connector
1)
Not possible with surface mounting housing (position 9 = B). For the surface mounted version, please order a device
with the appropriate electrical RS485 interface and accessories as stated in
under "External Converters"
2)
Cannot be delivered in connection with 9th digit = B.
Function Interface (rear side, port C)
DIGSI/Modem/Browser, electrical RS232
DIGSI/Modem/Browser/RTD-box, electrical RS485
For further interface options see Additional Specification M
Additional Specification M for Further Function Interfaces
(device rear port C and D) (only if pos. 12 = 9)
Port C: DIGSI/Modem/Browser, electrical RS232
Port C: DIGSI/Modem/Browser/RTD-box, electrical RS485
Port D: RTD-box, optical, 820 nm, ST connector
Port D: RTD-box, electrical RS485
1)
In case of a connection to a RTD box 7XV5662-xAD10, a RS485-LWL converter 7XV5650-0xA00 is required.
Measurement Function
Basic measured values
Minimum and Maximum Values
Basic measured values, average values, min/max values, transformer monitoring functions (connection to RTD
box/hot-spot, overload factor)
1)
Only in connection with position 12 = 2 or 9 and Mxx (supplementary)
Differential Protection
Differential Protection + Basic Functions
Differential protection transformer, generator, motor, busbar
Overload protection in accordance with IEC 60354 for a winding
Lock out
Time overcurrent protection, phases: Ι>, Ι>>, Ιp (inrush restraint)
Time overcurrent protection 3Ι0: 3Ι0>, 3Ι0>>, 3Ι0p (inrush restraint)
Time overcurrent protection earth: ΙE>, ΙE>>, ΙEp (inrush restraint)
Differential protection + Basic elements + Ancillary functions
Restricted earth fault protection
Definite-time, single-phase, e.g. high-impedance earth fault protection (87G without resistor or varistor)
tank leakage protection,
Unbalanced load protection
Breaker failure protection
Trip circuit supervision
16.7 Hz, Railway Protection Transformer + Generator
16.7 Hz, Railway Protection Transformer + Generator + Busbar
SIPROTEC 4, 7UT6x, Manual
C53000-G1176-C230-5, Edition 09.2016
2)
2)
1)
1)
1)
4)
A.2 Differential Protection 7UT613 for 3 Measuring Locations
2)
A Ordering Information and Accessories
2)
4)
Ordering Information and Accessories
Pos. 21
Pos. 22
0
E
0
G
0
H
0
R
0
S
Pos. 12
1
2
9
Pos. 23
Pos. 24
1
2
A
F
Pos. 13
1
2
4
Pos. 14
A
B
3)
or
C
D
475