Siemens SIPROTEC 4 7UT6 Series Manual page 478

Differential protection
Table of Contents

Advertisement

Ordering Information and Accessories
A.3 1.1.3 Differential Protection 7UT633 and 7UT635 for 3 to 5 measuring locations
System Interfaces (rear side, port B)
Profibus FMS Slave, optical, single ring, ST connector
Profibus FMS Slave, optical, double ring, ST connector
For more interface options see Additional Specification L
1)
Not possible with surface mounting housing (position 9 = B). For the surface mounted version, please order a device
with the appropriate electrical RS485 interface and accessories as stated in
under "External Converters"
Additional Specification L for Further System Interfaces (device rear port B)
(only if Pos. 11 = 9)
Profibus DP Slave, RS485
Profibus DP Slave, optical, 820 nm, double ring, ST connector
Modbus, RS485
Modbus, optical, 820 nm, ST connector
DNP3.0, RS485
DNP3.0, optical, 820 nm, ST connector
IEC 61 850, 100 Mbit Ethernet, doppelt electrical, RJ45 connector
IEC 61 850, 100 Mbit Ethernet, optical, Duplex-LC connector
1)
Not possible with surface mounting housing (position 9 = B). For the surface mounted version, please order a device
with the appropriate electrical RS485 interface and accessories as stated in
under "External Converters"
2)
Cannot be delivered in connection with 9th digit = B
Function Interface (rear side, port C)
DIGSI/Modem/Browser, electrical RS232
DIGSI/Modem/Browser/RTD-box, electrical RS485
For further interface options see Additional Specification M
Additional Specification M for Further Function Interfaces
(device rear port C and D) (only if Pos. 12 = 9)
Port C: DIGSI/Modem/Browser, electrical RS232
Port C: DIGSI/Modem/Browser/RTD-box, electrical RS485
Port D: RTD box, optical, 820 nm, ST connector
Port D: RTD box, elektrical RS485
1)
In case of a connection to a RTD box 7XV5662-xAD10, a RS485-LWL converter 7XV5650-0xA00 is required
Measurement Function
Basic measured values
Basic measured values, average values, min/max values
Basic measured values, average values, min/max values, transformer monitoring functions (connection to RTD
box/hot-spot, overload factor)
1)
Only in connection with position 12 = 2 or 9 and Mxx (supplementary)
478
1)
1)
2)
2)
1)
1)
A Ordering Information and Accessories
1)
2)
A Ordering Information and Accessories
C53000-G1176-C230-5, Edition 09.2016
Pos. 11
5
6
9
Pos. 21
Pos. 22
0
A
0
B
0
D
0
E
0
G
0
H
0
R
0
S
Pos. 12
1
2
9
Pos. 23
Pos. 24
1
2
A
F
Pos. 13
1
2
4
SIPROTEC 4, 7UT6x, Manual