First Power ON.
Upon powering the drive on for the rst time you must set the region in Menu
After initial start-up you may change the region by setting the value of H101. See page 4-4 of FRENIC-ACE Instructional Manual INR-SI47-1733f-E For
more details.
Changing the regional from default value
Quick Start Menus
1.F Fundamental Functions
1.E Extension Terminal Functions
1.C Control Functions of Frequency
1.P Motor 1 Parameters
1.H High Performance Functions
1.H1 High Performance Functions
1.A Motor 2 Functions
1.J Application Functions
1.J1 PID Functions
1.d Application Functions 2
1.U Customizable Logic
1.U1 Customizable Logic
1.Y Link Functions
1.k Keypad Functions
2. rEP (Data Check)
Displays function codes that
have been changed from
factory default
3.
oPE (Operations Monitor)
3_00
Output frequency Before Slip
3_01
Output frequency After Slip
3_02
Output Current
3_03
Output Voltage
3_04
Calculated Torque
3_05
Reference Frequency
3_06
Rotation Direction
3_07
Running Status
3_08
Motor Speed r/min
3_09
Load Shaft speed
3_10
PID SV
3_11
PID PV
3_12
Torque Limit Value A
3_13
Torque Limit Value B
3_14
Ratio Setting
3_15
Line Speed r/min
Fuji Electric Corp. of America
47520 Westinghouse Drive, Fremont, CA 94539
Phone: 510-440-1060
www.americas.fujielectric.com
asia
amer
to
requires pressing and holding
+
1.F
_ _
1.E
_ _
1.C
_ _
1.P
_ _
1.H
_ _
1.H1
_ _
1.A
_ _
1.J
_ _
1.J1
_ _
1.d
_ _
1.U
_ _
1.U1
_ _
1.Y
_ _
1.k
_ _
To access menus 2-6 change function code E52-2
2. rEP
3. oEP
4. I_O
5. CHE
6. AL
4. I_O (I/O Check)
4_00 I/O Signals on the Control Card Terminals
4_01 I/O Signals on the Control Card Terminals
under Communications.
4_02 Input Voltage on Terminal 12
4_03 Input Current on Terminal C1
4_04 Output Voltage on Terminal FMV
4_05 Output Voltage on Terminal FM2
4_06 Output Frequency on Terminal FMP
4_07 Input Voltage on Terminal C1
4_08 Output Current on Terminal FMI
4_09 Output Current on Terminal FM2
4_24 Cutomizable Logic Timer
8.des
, for Americas by setting the value to
key while pressing
jpn
asia
chn
eu
amer
kor
5. CHE (Maintenacne Info)
5_00 Accumulated Run Time
5_01 DC Link Bus Voltage
5_03 Max Temperature of Heat Sink
5_04 Max Effectice Current
5_05 Capacitance of the DC Link Bus
5_06 Accumutated Run Time of Electolytic
5_07 Accumulated Run Time of Cooling Fan
5_08 Number of Starts (Drive)
5_09 Input Watt-Hour
5_10 Input Watt-Hour Data
6. AL (Alarm Info)
6_00 Output Frequency
6_01 Output Current
6_02 Output Voltage
6_03 Calculated Torque
6_04 Reference Frequency
6_05 Rotational Ditection
6_06 Running Status
6_07 Accumulated Running Time
6_08 Number of Startups
6_09 DC Link Bus Voltage
6_10 Temperature Inside the Inverter
6_11 Max. Temperature of Heat Sink
6_12 Terminal I/O Status
6_13 Terminal Input Signal Status in HEX
6_14 Terminal Output Status in Hex
6_15 Number of Consecutice Occurrces
6_16 Overlapping Alarm 1
6_17 Overlapping Alarm 2
6_18 Communication Terminal Status I/0
6_19 Communication Terminal Status Input
6_20 Communication Terminal Status Output
6_21 Sub-Code
6_22 Running Status 2
6_23 Detected Speed
6_24 Running Status 3
6_25 Multiple Alarm Sub-Code
amer
savue
Capacitance
Capacitors on the PCB