GIRBAU RMS610 Operating Instructions Manual page 26

Vended
Hide thumbs Also See for RMS610:
Table of Contents

Advertisement

Dosings
This allows the user to activate or deactivate the dosing signals that appear in the master table.
If product dosing occurs via the machine's dispenser, the dosing options are as follows (see dispenser
distribution in Section 4.3).
OPTIONS
MEANING
d- 0
Without dosing
d- 1
Powdered detergent. Normally used in the pre-wash phase
d- 2
Powdered detergent. Normally used in the wash phase
d- 3
Liquid product. Normally used for bleaching (chloride, bleach, etc.)
d- 4
Liquid product. Normally used as a softener/neutraliser
n.p.
Dosing cannot be programmed in the phase
Other possible programming options:
OPTIONS
MEANING
d-12
Simultaneous activation of dosings 1 and 2.
d-13
Simultaneous activation of dosings 1 and 3.
d-14
Simultaneous activation of dosings 1 and 4.
d-23
Simultaneous activation of dosings 2 and 3.
d-24
Simultaneous activation of dosings 2 and 4.
d-34
Simultaneous activation of dosings 3 and 4.
The 2 key allows the user to modify the option displayed.
The 1 key validates the selection on the display and allows the user to access the following programmable
function.
Phase 1 peculiarity
Application designed for machines connected to an external dosing control unit and using this unit's
own dosing programs.
Phase 1 allows the value 0 to be programmed in the level, rotation time and bath draining functions, using the
dosing and dosing time signals to inform the central dosing unit of the program selected in the washer. After
receiving this information, the central dosing unit will execute the appropriate product dosings for the program
selected in the washer.
Examples of first phase programming used as information to the central dosing unit
Example 1
d
t
1
30
Dosing in accordance with Program 1
2
30
Dosing in accordance with Program 2
3
30
Dosing in accordance with Program 3
4
30
Dosing in accordance with Program 4
Example 2
d
t
1
2
Dosing in accordance with Program 1
1
4
Dosing in accordance with Program 2
1
6
Dosing in accordance with Program 3
1
8
Dosing in accordance with Program 4
CAUTION!
When dosing signals d3 and d4 are used to inform the central dosing unit, it is advisable to activate the dC
(dispenser cleaning) option in order to remove traces of water from the dispenser. (See Mod menu, Chapter
9)
Modification of the program contents
information
information
26
Cod. 598144
Rev. 11/0717

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents