Service Manual - First Edition
How to Check the Resistance
of a Valve Coil
1 Turn the key switch to the
disconnect the wires from the valve coil to be
tested.
2 Connect the leads from an ohmmeter to the
valve coil terminals.
Valve coil specifications
Proportional solenoid valve
3 position 4 way directional valve
Normally closed poppet valve
Part No. 34032
position and
OFF
5W
4.5W
7W
Genie S-80 & Genie S-85
Section 7 - Repair Procedures
FUNCTION MANIFOLDS
7 - 39