Connecting The Target System (As Occasion Demands) - Renesas Compact Emulator M30620T-CPE User Manual

Compact emulator for m16c/62 group m16c/62a
Table of Contents

Advertisement

2.5 Connecting the Target System (as occasion demands)

Connect the LCC probe on the lower board of the emulator to the LCC socket (option) or the pitch
converter board (option).
Figure 2.8 LCC probe on the lower board of the emulator
Some MCU packages need the pitch converter board (option) shown in Figure 2.9. When connecting
it, be sure to check the position of No. 1 pin.
Figure 2.9 Connecting target system
Notes on Connecting Target Systems:
LCC probe at the lower board of compact emulator
80-pin
0.65-mm-pitch
M3T-100LCC-80QSB
80-pin QFP
(option)
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the compact emulator.
• Always shut OFF power of the emulator and the target system when connecting and
disconnecting the target system.
( 22 / 52 )
100-pin
0.65-mm-pitch
LCC socket
100-pn LCC
(option)
CAUTION
0.5-mm-pitch
M3T-100LCC-QSD
100-pin LQFP
(option)

Advertisement