Troubleshooting When Emulator Debugger Pd30M Starts Up - Renesas Compact Emulator M30620T-CPE User Manual

Compact emulator for m16c/62 group m16c/62a
Table of Contents

Advertisement

Table 5.2 Error display and how to remedy it when starting up the emulator (2/2)
LED display
Connection to the
: OFF
: Blinking
POWER CLOCK
RESET
RUN
POWER CLOCK
RESET
RUN
POWER CLOCK
RESET
RUN
POWER CLOCK
RESET
RUN
POWER CLOCK
RESET
RUN
POWER CLOCK
RESET
RUN
POWER CLOCK
RESET
RUN
POWER CLOCK
RESET
RUN
POWER CLOCK
RESET
RUN

(2) Troubleshooting When Emulator Debugger PD30M Starts Up

Table 5.3 lists error messages and how to remedy them when starting up PD30M.
Table 5.3 Error message and how to remedy it when starting up PD30M
Error message
Communication ERROR.
Can't accept data.
Not Compact Emulator.
Target MCU is not given clock.
Please reset target systems.
Target MCU is unable to reset.
Please reset target systems.
The version of PD30M and the
firmware on the target are not same.
Please download the firmware
to target.
target system
Emulator does not work properly.
-
- The emulator may be damaged. Report LED status to
your local distributor.
Connection to the
target system
-
-
Connected
Not connected
Connected
Not connected
-
-
( 42 / 52 )
Checkpoint
Checkpoint
- Check the emulator's target status LEDs. If
flashing, the emulator is not working properly.
Check settings as explained in "(1)
Troubleshooting When the Emulator Starts
Up".
- Check the connected serial port and the serial
port settings in the Init dialog box match.
- Try lowering the baud rate in the Init dialog
box.
- Check the connected serial port and the serial
port settings in the Init dialog box match.
- Check an emulator (such as PC4701M,
PC4701HS or PC4701L) is not connected.
- Check the target system's oscillation circuit
works properly when the Clock tab in the Init
dialog box is set to External.
- If the Clock tab in the Init dialog box is set to
External, change it to Internal.
- Check the target system's oscillation circuit
works properly when the Clock tab in the Init
dialog box is set to External.
- If the Clock tab in the Init dialog box is set to
External, change it to Internal.
- Contact your local distributor.
- Contact your local distributor.

Advertisement

Table of Contents
loading

Table of Contents