The modifier character is the sum of the applicable option values based
on the following table.
Code Type
Code 39
Code 128
EAN/UPC
Interleaved
2 of 5
Option Value
0
No Check character or Full ASCII processing.
1
Reader has checked one check character.
2
Reader has stripped check character.
Reader has performed Full ASCII character
4
conversion.
A Full ASCII bar code 1234 with check character W,
Example:
A+I+MI+DW, can be transmitted as ]A71234 where
7 = (1+2+4).
Standard data packet. No Function code 1 in first
0
symbol position.
1
Function code 1 in first symbol character position.
2
Function code 1 in second symbol character position.
A Code (EAN) 128 bar code 12345 with Function 1
Example:
character in the first position,
transmitted as ]C112345.
Standard packet in full EAN country code format,
0
which is 13 digits for UPC-A and UPC-E (not including
supplemental data).
1
Two digit supplement data only.
2
Five digit supplement data only.
4
EAN-8 data packet.
A UPC-A bar code 012345678905 will be transmitted
Example:
as ]E00012345678905.
0
No check digit processing.
1
Reader has checked check digit.
2
Reader has stripped check digit before transmission.
An I 2 of 5 bar code without check digit, 4123 will be
Example:
transmitted as ]I04123.
Configuring the Scanner
Option
3–15
Fcnt1
12345 will
Publication 2755-6.2