Technical data
10.1 Technical data
Digital outputs
Table 10- 13 Digital outputs
Number of outputs
Supply voltage
Output voltage
Max. output current
Total current of the outputs
Extinguishing energy per output
Lamp load
Switching rate
Short-circuit protection
Max. leakage current
Output delay (Q0...Q7)
Electrical isolation between
outputs
Electrical isolation between
outputs and logic
Insulation
Length of cable
1) V
Note
The connecting cable between the voltage source and the load current supply connector L+
and the associated reference potential M should not exceed a maximum length of 10 m.
READY output (RDY)
Table 10- 14 Electrical parameters of RDY relay contact
RDY relay contact
Switching voltage DC
Switching current
Switching capacity
Mechanical service life
Electrical service life
178
- Supply voltage of outputs
L
8
24 V DC (permissible range: V
1 signal: From V
- 0.8 V to V
L 1)
1 signal: 5 mA. to 0.6 A (via supply voltage)
max. 4 A (at 0 to 40° C)
max. 2 A (at 40 to 55° C)
400 mJ (not simultaneous)
5 W
100 Hz (with resistive load)
2 Hz (with inductive load)
Yes
0 signal: 2 mA
0 → 1 signal: 500 μs (typically 150 μs) with RL = 60 Ohm
1 → 0 signal: 500 μs (typically 150 μs) with RL = 60 Ohm
No
Yes
500 V DC
Max. 30 m
max. 50 V
Max. 1 A
Max. 30 VA
Usually 10
9
Typically 3 · 10
= 20.4 to 28.8 V)
L
V
L 1)
switching cycles
switching cycles at 24 V / 1 A
6
Operating Instructions, 02/2012
SIMOTION C