Siemens SIMOTION C Operating Instructions Manual page 173

Hide thumbs Also See for SIMOTION C:
Table of Contents

Advertisement

Onboard drive interface (C230-2, C240)
Analog
Table 10- 8
Setpoint signal (analog output)
Number
Rated voltage range
Output current
Electrically isolated
Load impedance
Resolution
Filter time
Basic error limit (at 25° C)
Relay contact controller enable
Number
Switching voltage
Switching current
Switching capacity
Mechanical service life
Electrical service life
Cable length: Max. 35 m
SIMOTION C
Operating Instructions, 02/2012
Onboard drive interface
C230-2
C240
0 V to 10 V
-10 V to 0 V
4
-10.5 to 10.5 V
-3 to 3 mA
No
≥ 3 kOhm
16-bit, including sign (with filter)
12-bit, including sign (without filter)
With filter (C230-2-compatible)
With filter (C230-2 compatible) or without filter (can
be switched in HW Config)
-2 to +6 % (typically +3 %)
-6 to +2 % (typically -3 %)
4
max. 50 V
Max. 1 A
Max. 30 VA
Usually 10
switching cycles
9
Typically 3 · 10
switching cycles at 24 V / 1 A
6
Technical data
10.1 Technical data
173

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents