Possible Uses Of Onboard Drive And Measuring System Interface In The Application (C230-2, C240); Overview - Siemens SIMOTION C Operating Instructions Manual

Hide thumbs Also See for SIMOTION C:
Table of Contents

Advertisement

3.7 Possible uses of onboard drive and measuring system interface in the application (C230-2, C240)

3.7
Possible uses of onboard drive and measuring system interface in
the application (C230-2, C240)
3.7.1

Overview

The onboard drive interface and the measuring system interface can be used in the
application for the technology objects TO axis and TO externalEncoder, and for I/O variable.
The table below lists the combination possibilities for the C230-2/C240.
Table 3- 16
Position axis
Drive axis
External encoder
Also for C240:
Standard output (I/O variables)
Standard input (I/O variables)
The incremental encoder used must not have a zero pulse
1)
Note
A standard output and a drive cannot be used simultaneously on one axis channel.
The input (X3 to X6) used as a counter input cannot be used simultaneously as an encoder
input.
When a project is created and when a project is downloaded, a consistency check of the
permitted combinations per axis channel is automatically performed.
SIMOTION C
Operating Instructions, 02/2012
Combination possibilities for the C230-2/C240
Application
Analog output (PQW)
Digital output (PQ)
Counter input (PIW)
Output (X2)
1)
Axis channel
Input (X3 to X6)
x
x
-
x
x
-
Interfaces
x
-
x
-
-
x
63