Connecting User System Interface Cable To User System; Installing Ic Socket; Soldering Ic Socket; Inserting Cable Head - Renesas H8/330 User Manual

User system interface cable for e6000 emulator
Table of Contents

Advertisement

2.2

Connecting User System Interface Cable to User System

Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before connecting,
make sure that pin 1 on both sides are correctly aligned. Failure to
do so will damage the user system and the emulator product or will
result in PERSONAL INJURY. The USER PROGRAM will be
LOST.
To connect the cable head to the user system, follow the instructions below.
2.2.1

Installing IC Socket

After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of
the IC socket for an FP-80A package, and fasten it to the user system before soldering.
2.2.2

Soldering IC Socket

After fastening, solder the IC socket for an FP-80A package to the user system. Be sure to
completely solder the leads so that the solder slops gently over the leads and forms solder fillets.
(Use slightly more solder than the MCU.)
2.2.3

Inserting Cable Head

Check the location of pin 1 before inserting.
Align pin 1 on the IC socket for an FP-80A package on the user system with pin 1 on the user
system interface cable head, and insert the user system interface cable head into the IC socket on
the user system, as shown in figure 3.