Iq6Plus-72-2-Us Microinverter Specifications - enphase IQ6-60-2-US Installation And Operation Manual

Hide thumbs Also See for IQ6-60-2-US:
Table of Contents

Advertisement

IQ6PLUS-72-2-US Microinverter Specifications

Topic
Commonly used module pairings
Peak power tracking voltage
Operating range
Maximum DC input voltage
Minimum / maximum start voltage
Maximum DC input short circuit current (module Isc)
Overvoltage class DC port
DC Port backfeed under single fault
PV array configuration
Maximum continuous AC output power (-40 to
+65C)
Peak output power
Power factor (adjustable)
Nominal AC output voltage range
240 VAC (single phase)
208 VAC (single phase)
Nominal output current
240 VAC (single phase)
208 VAC (single phase)
Nominal frequency
Extended frequency range
Maximum AC output over current protection device
Maximum AC output fault current & duration
High AC voltage trip limit accuracy
Low AC voltage trip limit accuracy
Frequency trip limit accuracy
Trip time accuracy
Overvoltage class AC port
AC port backfeed under single fault
Power factor at rated power
38
IQ6PLUS-72-2-US Microinverter Parameters
DC Parameters
1 x 1 ungrounded array; No additional DC side protection
AC Parameters
© 2017 Enphase Energy Inc. All rights reserved.
IQ 6 / IQ 6+ Micro Installation and Operation
Unit
Min
W
V
27
V
16
V
V
22
A
A
required; AC side protection requires max 20 A per
branch circuit
VA
VA
Vrms
211
Vrms
183
Arms
Arms
Hz
Hz
47
A
mA rms for 6
cycles
1.0
%
1.0
%
%
±0.1
milliseconds
±33
A
Typical
Max
235 W - 400+ W
36
45
62
62
62
15
II
0
280
290
0.7 leading
0.7 lagging
240
264
229
1.17
1.35
60
68
20
850
III
0
1.0
141-00034-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iq6plus-72-2-usIq 6 micros

Table of Contents