enphase IQ6-60-2-US Installation And Operation Manual page 39

Hide thumbs Also See for IQ6-60-2-US:
Table of Contents

Advertisement

Maximum microinverters per 20 amp (max) AC
branch circuit
240 VAC (single phase)
208 VAC (single phase)
CEC weighted efficiency
240 VAC (single phase)
208 VAC (single phase)
Static MPPT efficiency (weighted, ref EN 50530)
Total harmonic distortion
Ambient temperature range
Night tare loss
Storage temperature range
Compatibility
Dimensions not including mounting bracket
Connector type
Weight
Environmental category / UV exposure rating
Torque specifications for fasteners
(Do not over torque)
Cooling
Relative humidity range
Approved for wet locations
Pollution degree
Communication
Standard warranty term
Compliance
Grounding
Monitoring
Integrated DC disconnect
Integrated AC disconnect
39
IQ6PLUS-72-2-US Microinverter Parameters
Miscellaneous Parameters
Features and Specifications
Pairs with most 60 and 72-cell PV modules
219 mm x 191 mm x 37.9 mm (approximate)
MC-4 locking type
1.5 kg (3 lbs.)
Outdoor NEMA 250, type 6 (IP67)
Natural convection - no fans
4% to 100% condensing
Yes
PD3
Power line
enphase.com/warranty
UL62109, UL1741/IEEE1547, FCC Part 15 Class B,
ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01
This product is UL Listed as PV Rapid Shut Down
Equipment and conforms with NEC-2014 and NEC-2017
section 690.12 and C22.1-2015 Rule 64-218 Rapid
Shutdown of PV Systems, for AC and DC conductors,
when installed according manufacturer's instructions.
The DC circuit meets the requirements for ungrounded
PV arrays in NEC. Ground fault protection (GFP) is
integrated into the class II double insulated microinverter.
Enlighten Manager and MyEnlighten monitoring options
require an Enphase IQ Envoy
The DC connector has been evaluated and approved for
use as the load-break disconnect required by NEC 690.
The AC connector has been evaluated and approved for
use as the load-break disconnect required by NEC 690.
© 2017 Enphase Energy Inc. All rights reserved.
IQ 6 / IQ 6+ Micro Installation and Operation
%
97.0
96.5
%
99.5
%
C
-40
mW
C
-40
6 mm (1/4") mounting hardware: 5 N m (45 to 50
in-lbs.)
8 mm (5/16") mounting hardware: 9 N m (80 to
85 in-lbs.)
When using UL 2703 mounting hardware, use
the manufacturer's recommended torque value
13
11
5
+65
50
+85
141-00034-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iq6plus-72-2-usIq 6 micros

Table of Contents