COMMUNICATION
CODE
DESCRIPTION
85
Water Evaporator,Water Outlet T°,Faulty Probe
Electrical Box T°,Air T°,Faulty Probe
89
90
Water Freecooling,Inlet T°,Faulty Probe
102
Circuit 1,Fan Condenser Motor,Electrical Failure
103
Circuit 1,Fan Condenser Inverter,Electrical Failure
104
Circuit 1/2,Fan Condenser Motor,Electrical Failure
105
Circuit 1/2,Fan Condenser Inverter,Electrical Failure
108
Unit,Power Factor CosPhi,Electrical Failure
Circuit 1,Leak Refrigerant,Detection
110
111
Circuit 1 Compressor 1,Discharge T°,Overheating
112
Circuit 1,Discharge T° Compressor 2,Overheating
113
Circuit 1,Discharge T° Compressor 3,Overheating
114
Circuit 1,Compressor(s),Electrical Failure
115
Circuit 1,Safety High Pressure,Cut Off
116
Circuit 1,Reversing Valve,Blocked
Circuit 1, Safety Low Pressure,Cut Off
117
118
Circuit 1,Water Evaporator,Risk Of Frosting
Circuit 1,Evaporator Superheat,Too High
121
122
Circuit 1,Evaporator Superheat,Too Low
123
Circuit 1,Condenser Subcooling,Too High
124
Circuit 1,Condenser Subcooling,Too Low
127
Circuit 1,MOP,Maximum Operating Pressure
Circuit 1,LOP,Low Operating Pressure
128
129
Circuit 1,Condenser T°,Too High
Circuit 1,EEV Valve,Not Closed
131
132
Circuit 1,EEV Motor,Failure
141
Circuit 1,High Pressure,Faulty Sensor
142
Circuit 1,Low Presure,Faulty Sensor
143
Circuit 1,Liquid T°,Faulty Probe
144
Circuit 1,Suction T°,Faulty Probe
145
Circuit 1,Discharge T° Compressor 1,Faulty Probe
Circuit 1,Discharge T° Compressor 2,Faulty Probe
146
147
Circuit 1,Discharge T° Compressor 3,Faulty Probe
148
Circuit 1,Water Condenser Inlet T°,Faulty Probe
149
Circuit 1,Water Condenser Outlet T°,Faulty Probe
202
Circuit 2,Condenser Fan Electrical Failure
203
Circuit 2,Condenser Inverter Electrical Failure
210
Circuit 2,Leak Refrigerant Detected
Circuit 2,Discharge T° Compressor 2, Overheating
211
212
Circuit 2,Discharge T° Compressor 2, Overheating
Circuit 2,Discharge T° Compressor 3, Overheating
213
214
Circuit 2,Compressor, Electrical Failure
215
Circuit 2,High Pressure Cut Off
216
Circuit 2,Reversing Valve, Blocked
217
Circuit 2, Safety Low Pressure,Cut Off
Circuit 2,Evaporator, Risk Of Frosting
218
219
Circuit 2,Low Condensing T°
Circuit 2,Evaporator Superheat Too High
221
222
Circuit 2,Evaporator Superheat Too Low
223
Circuit 2,Condenser Subcooling Too High
224
Circuit 2,Condenser Subcooling Too Low