Trigger Level Range
Trigger Level
Accuracy, typical
(Accuracy is for
signals having rise
and fall times ≥20ns)
Set Level to 50%,
typical
Note: Bandwidth reduced to 6MHz when using a 1X probe.
Video Trigger Type
Signal Formats and
Field Rates, Video
Trigger Type
Holdoff Range
Pulse Width Trigger
Pulse Width Trigger
Mode
Pulse Width Trigger
Point
Pulse Width Range
DSO4000 Series Digital Storage Oscilloscope
EXT/5
AC
Attenuates signals below 10Hz
HF Reject
Attenuates signals above 80kHz
Same as the DC-coupled limits for frequencies above
LF Reject
150kHz; attenuates signals below 150kHz
Source
Range
CH1, CH2
± 8 divisions from center of screen
EXT
± 1.2V
EXT/5
± 6V
Source
Accuracy
0.2div × volts/div within ± 4 divisions from center of
CH1、CH2
screen
EXT
± (6% of setting + 40mV)
EXT/5
± (6% of setting + 200mV)
Operates with input signals ≥50Hz
Source
CH1, CH2
EXT
EXT/5
Supports NTSC, PAL and SECAM broadcast systems for any field or
any line
100ns to 10s
Trigger when < (Less than), > (Greater than), = (Equal), or ≠ (Not Equal);
Positive pulse or Negative pulse
Equal: The oscilloscope triggers when the trailing edge of the pulse
crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger
point is the trailing edge. Otherwise, the oscilloscope triggers when a
pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers
when a pulse continues longer than the time specified as the Pulse
Width.
Selectable from 20ns to 10s
1V from DC to 100MHz
Range
Peak-to-peak amplitude of 2 divisions
400mV
2V
Specifications
1V from DC to
100MHz;
1.75V from
100MHz to
200MHz
71