2.7 Vertical System

2.7.1 Vertical Controls

Vertical controls can be used to display and remove waveforms, adjust vertical scale and position,
set input parameters and perform math calculations. Each channel has a separate vertical menu
to set. See below for menu description.
1. VERTICAL POSITION Knob
Move the channel waveform up and down on the screen. In dual-window mode, move the
waveforms in both windows at the same time in a same direction. Push this knob to return
waveforms to the vertical center position on the screen. Two channels correspond to two knobs.
2. VOLT/DIV Knob
Control the oscilloscope to magnify or attenuate the source signal of the channel waveform. The
vertical size of the display on the screen will change (increase or decrease) to the ground level.
Also you may use this knob to switch between coarse and fine.
3. Menu (CH1, CH2): Display vertical menu options; turn on or off the display of channel
waveforms.
Options
Coupling
20MHz Bandwidth
Limit
VOLTS/DIV
DSO4000 Series Digital Storage Oscilloscope
Settings
Comments
DC passes both DC and AC components of the input signal.
DC
AC blocks the DC component of the input signal and
AC
attenuates signals below 10Hz.
Ground
Ground disconnects the input signal.
Limits the bandwidth to reduce display noise; filters the
Unlimited
signal to eliminate noise and other unnecessary HF
Limited
components.
Selects the resolution of the VOLTS/DIV knob.
Coarse
Coarse defines a 1-2-5 sequence. Fine changes the
Fine
resolution to small steps between the Coarse settings.
VERTICAL POSITION Knob
VOLT/DIV Knob
Basic Operation
15