Example 11: Measuring Data Propagation Delay - Hantek DSO4072 User Manual

Dso4000 series. digital storage oscilloscope
Hide thumbs Also See for DSO4072:
Table of Contents

Advertisement

CH2.
Follow the above steps to set up the Math menu, and observe the subtracted waveform as shown
in the figure below.
Those in pink are added waveforms.

3.11 Example 11: Measuring Data Propagation Delay

When you doubt that there appear instabilities in a serial data propagation control circuit, you can
set the oscilloscope to measure the propagation delay between the enable signal and the transfer
data.
To set the propagation delay measurement, follow the steps below.
1.
Connect two oscilloscope probes respectively to the CS (chip-select) pin and the DATA pin on
the chip.
2.
Set the Probe option attenuation to 10X for both probes.
3.
Open CH1 and CH2 at the same time, both with the attenuation of 10X.
4.
Push the AUTOSET button to trigger a stable waveform display.
5.
Adjust the horizontal and vertical controls to optimize the waveform display.
6.
Push the CURSOR button to view the Cursor menu.
7.
Push the Type option button and select Time.
8.
Select Cursor S and turn V0 to place it on the active edge of the enable signal.
9.
Select Cursor E and turn V0 to place it on the data output transition (See the figure below).
10. Read the data propagation delay in the Delta readout.
DSO4000 Series Digital Storage Oscilloscope
66

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dso4202Dso4102

Table of Contents