Proceq Profometer 5+ Operating Instructions Manual page 24

Rebar detection system
Table of Contents

Advertisement

5.5.1
Measuring with the Mobile Probe
• Scan the area to be measured with the mobile probe
(see «ScanCar», page 5) while observing the selected
grid.
Fig. 5.14 Measuring with the mobile probe
Direction of travel:
The front of the mobile probe is where the
single wheel is.
The front must always be opposite the x or y
axis. The direction of travel can be forward or
backward.
18
Measuring Process
Upper limit of object
Marking the travel paths acc.
to x/y-grid
Rebar of 1st layer
Left limit of object
• Pressing the END key calls the top left corner of the
measuring area:
1
5
4
3 2
Fig. 5.15 Measuring area before measuring
Key:
1 Cursor:
Press the ↑, ↓, ←, → keys briefly to move the cursor
step by step.
Keep the ↑, ↓, ←, → keys permanently pressed to go
to the next pages.
2 The arrow indicates the measuring direction. With the
↑, ↓, ←, → keys the measuring direction can be
changed.
3 Current concrete cover
4 Grey scale symbol of the current concrete cover
5 From 10 m in direction x, 10 a.s.o. is displayed.
• Follow the instructions in the display of Fig. 5.15 before
starting measuring.
The x/y-coordinates are indi-
cated in meters or feet.
One page contains 16 x 15
measured values that are
displayed in grey scale and
stored. The memory has a sto-
rage capacity of 500 pages.
The number of the remaining
free pages is indicated in the
measuring display (see Fig.
5.13).
© 2007 Proceq SA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SScanlog

Table of Contents